Change search
ReferencesLink to record
Permanent link

Direct link
Thermal Shape Factor: The impact of the building shape and thermal properties on the heating energy demand in Swedish climates
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2016 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

In the year 2006, the energy performance directive 2002/91/EG was passed by the European Union, according to this directive the Swedish building code was supplemented by a key measure of energy use intensity (EUI). The implemented EUI equals some energy use within a building divided by its floor area and must be calculated in new housing estate and shown when renting or selling housing property. In order to improve the EUI, energy efficiency refurbishments could be implemented. Building energy simulation tools enables a virtual view a building model and can estimate the energy use before implementing any refurbishments. They are a powerful resource when determine the impact of the refurbishment measure. In order to obtain a correct model which corresponds to the actual energy use, some adjustments of the model are often needed. This process refers to as calibration.

The used EUI has been criticized and thus, the first objective in this work was to suggest an alternative key measure of a buildings performance. The results showed that the currently used EUI is disfavoring some districts in Sweden. New housing estate in the far north must take more refined actions in order to fulfill the regulation demand, given that the users are behaving identical regardless where the house is located. Further, the suggested measure is less sensitive to the users’ behavior than the presently used EUI. It also has a significance meaning in building design as it relating the building shape and thermal properties and stating that extreme building shapes must undergo a stricter thermal construction rather than buildings that are more compact. Thus, the suggested key measure also creates a communication link between architects and the consultant constructors.

The second objective of this thesis has been to investigate a concept of calibration using the data normally provided by energy bills, i.e. some monthly aggregated data. A case study serves to answer this objective, by using the building energy simulation tool IDA ICE 4.7 and a building located in Umeå, Sweden. The findings showed that the used calibration approach yielded a model considered as calibrated in eleven of twelve months. Furthermore, the method gives a closer agreement to the actual heat demand rather than using templates and standardized values. The major explanation of the deviation was influence of the users, but also that the case study building burden with large heat losses by domestic hot water circulation and thus, more buildings should be subjected to this calibration approach. 

Place, publisher, year, edition, pages
2016. , 44 p.
Keyword [en]
Heat loss coefficient, Building shape, Thermal properties, Calibration
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:umu:diva-125076OAI: oai:DiVA.org:umu-125076DiVA: diva2:957870
Subject / course
Energiteknik
Educational program
Master of Science Programme in Energy Engineering
Supervisors
Examiners
Available from: 2016-09-06 Created: 2016-09-05 Last updated: 2016-09-06Bibliographically approved

Open Access in DiVA

fulltext(1834 kB)5 downloads
File information
File name FULLTEXT01.pdfFile size 1834 kBChecksum SHA-512
7978bc1deb7a8dcf5e6c6264db37d1ffb0f5b2021c25d2cb8b61770fdf2f6c14e96a6fa94fdf8f437a28fab311bc4b487454ed4c3d5dd2a4915a780af196faa9
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 5 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 14 hits
ReferencesLink to record
Permanent link

Direct link