Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Uppföljning av energibalansberäkning på Melonen 4
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2016 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 300 HE creditsStudent thesisAlternative title
A comparison between simulated and actual energy demand at Melonen 4 (English)
Abstract [sv]

Tankesättet kring byggnaders energianvändning har inte alltid varit så fokuserad på energieffektivt som den är i dagsläget, utan hade under en lång tid handlat mer om ekonomi. Användandet av energisimuleringar är idag ett centralt verktyg för att undersöka om nybyggnationer eller renoveringar av byggnader uppfyller de krav som ställs. Däremot är det komplicerat att under projekteringen förutse en byggnads olika energibehov, vilket ofta leder till avvikelser mellan energisimuleringar och det verkliga driftfallet. Det är emellertid svårt att i verkligheten bestämma de olika energibehoven då separata mätningar ofta saknas, vilket medför användandet av antaganden. Detta begränsar ofta de slutsatser som dras efter en uppföljning och gör det intressant att särskilja vad avvikelserna i byggnadens energibehov kan bero på.

I detta examensarbete har det huvudsakliga syftet varit att genomföra en uppföljning av renoverade bostadshus och undersöka orsaken till avvikelser mellan simulerat och verkligt energibehov. Utifrån de bidrag som ingår i byggnadens specifika energianvändning har jämförelser gjorts mellan antaganden och faktiskt uppmätt statistik. Samtliga faktorer som bidrar till byggnadens energianvändning är inte mätbara, men utifrån arbetets tidsram har möjliga mätningar genomförts. Den tillgängliga energistatistiken kommer från AB Bostadens mätningar vid Melonen 1 (huvudmätare) och separat mätning i typhusen (undermätare).

Resultatet i denna examensrapport visade på en avvikelse mellan VIP-beräkningen och undermätningen på ungefär +8 % hos energianvändningen i typhus 1 och +18 % i typhus 2, före korrigering. Vid jämförelse mellan VIP-beräkningen och huvudmätningen erhölls en avvikelse på ungefär +8 % för byggnadernas energianvändning, vilket även här var före korrigering. Korrigeringen av VIP-beräkningen visade på att byggnadsmodellen stämde bra med verkligheten och orsaken till avvikelserna bedömdes bero på felaktiga antaganden på posterna tappvarmvattenbehov, fastighetsel och hushållsel. Undersökningen av den teoretiska värmefördelningen visade på att den gav en bra uppskattning av det aktuella värmebehovet. Utöver detta bedömdes mätaruppställningen för fastighetselanvändningen inte vara optimal vid en uppföljning, utan måste åtgärdas genom att separera de verksamhetselbidrag som också ingår.

Abstract [en]

While modern building code includes both economic and environmental aspects of constructing and operating buildings the main incentive in the past was only economy. In modern society there are several energy requirements which are stated by law and affects all buildings. Building energy simulation (BES) is therefore a common tool to utilize during planning, which indicates whether or not a building meets current energy requirements. However, the usage of BES-models often results in the need of different assumptions. Consequently, deviations between BES and actual energy demand are common and the conclusions that are drawn from the comparison.

The aim of this master thesis was to perform a control of energy demands in residential buildings and, if possible, to deduce reasons to any deviations between BES, conducted with VIP, and actual energy demand. Therefore any conclusions from this work could be used as guidelines in future BES and how to use sufficient measurements when conducting energy monitoring. Based on parameters that affect buildings energy demand, different comparisons have been made between assumptions and measured energy statistics. Measured data was available for two individual buildings and for the entire block.

When comparing the measurements with results from simulation in VIP, a deviation of +8 % and +18 % were obtained for energy demand in standard house 1 and 2. This was before altering specific energy needs that were obtained through assumptions during planning phase. For the entire block the deviation was found to be +8 %. After adjusting the VIP models with the actual use of electricity and domestic hot water the results from VIP simulations show that the constructed building models for standard house 1 and 2 are both good approximations. Therefore the origin of obtained deviations were concluded to be of faulty assumptions; both in BES and calculated data. In addition to this, it was also concluded that used theoretical heat distribution to assess the block’s energy offered a good estimation of the actual heating demand.

Place, publisher, year, edition, pages
2016. , 52 p.
Keyword [sv]
Uppföljning, energibalansberäkning
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:umu:diva-122104OAI: oai:DiVA.org:umu-122104DiVA: diva2:937280
External cooperation
WSP Umeå
Subject / course
Energiteknik
Educational program
Master of Science Programme in Energy Engineering
Presentation
2016-05-25, 15:00 (Swedish)
Supervisors
Examiners
Available from: 2016-06-15 Created: 2016-06-15 Last updated: 2016-06-15Bibliographically approved

Open Access in DiVA

fulltext(2034 kB)137 downloads
File information
File name FULLTEXT01.pdfFile size 2034 kBChecksum SHA-512
61cb8faef9958d3f829faca8399bf223fb26c06f2d357f23a40b48b385e41d996b54d0249e92f7dc6a360763ae4389087b974788781dc8f5e7c3307f83b4f227
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Jonsson, Jimmy
By organisation
Department of Applied Physics and Electronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 137 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 167 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf