Improved Algorithm for Measurement of Blood Pressure based on a Laser Doppler Flowmetry Signal
Linköping University, Department of Biomedical Engineering.
2016 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

People with diabetes suffer from a high risk of developing foot related diseases. It is therefore important to perform a blood pressure measurement on the toe to be able to diagnose and treat in time. Using laser Doppler flowmetry has been proven to be a useful technique for this purpose during a standard blood pressure measurement procedure using a cuff. The laser Doppler probe detects once the blood flow returns which can then be related to the pressure value.

However, the algorithm currently used by the company for detection of return of blood flow is in need of improvements. This thesis aims to develop an improved algorithm, which is more robust against artifacts. Furthermore, a warning system for uncertainties in the detection will be developed and integrated with the new algorithm.

To create the algorithm an investigation of the signals’ appearances was performed to obtain an understanding of what artifacts and characteristics the algorithm should be able to handle. First three different basic approaches were implemented and tested, namely model curve, threshold and pulsations. These algorithms were then combined into two different more complex algorithms. One of them consisted of the model curve and the pulsation algorithm, the second combined algorithm consisted of the threshold algorithm and the pulsation algorithm.

From the result it was found that the second combined algorithm performed best. It had a high accuracy and a well-functioning warning system. However, the algorithm had problems to correctly detect the return of flow when it is characterised by a slow increase of the perfusion. The biggest contribution by this thesis is the newly developed warning system. A false detection can lead to a false diagnose to be given if the operator is not attentive. The warning system is therefore an important feature since it can prevent this from occurring.

Place, publisher, year, edition, pages
2016. , 50 p.
Keyword [en]
Laser Doppler Flowmetry, blood pressure, diabetes, toe blood pressure, algorithm
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:liu:diva-129192ISRN: LiTH-IMT/BIT30-A-EX--16/534--SEOAI: oai:DiVA.org:liu-129192DiVA: diva2:936361
External cooperation
Perimed AB
Subject / course
Biomedical Instrumentation
Available from: 2016-06-22 Created: 2016-06-13 Last updated: 2016-06-22Bibliographically approved

Open Access in DiVA

fulltext(5420 kB)106 downloads
File information
File name FULLTEXT01.pdfFile size 5420 kBChecksum SHA-512
9b6c29633c82c13ded5ceffac4a1c70c167b080f2e0bc905fd8353efe515280e514ee9225b09106a4acc032a43fcd3737adbbe6b06dc9e553b9592398d4b52f5
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Mårtensson, Sofie
By organisation
Department of Biomedical Engineering
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 106 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 489 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf