Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Advanced Plasma Analyzer for Measurements in the Magnetosphere of Jupiter
Umeå University, Faculty of Science and Technology, Department of Physics. Swedish Institute of Space Physics.ORCID iD: 0000-0002-8713-7549
2016 (English)Doctoral thesis, monograph (Other academic)
Abstract [en]

The Jupiter Icy Moons Explorer is a planetary exploration mission that aims to study the moons of Jupiter in the planet’s vast magnetosphere. Among the various instruments on board is the Particle Environment Package (PEP), that is led by the Swedish Institute of Space Physics (IRF) in Kiruna. The Jovian plasma Dynamics and Composition analyzer (JDC) is one of six sensors within PEP and focuses on the characterization of positive ions. To be able to measure their three-dimensional distribution and composition, in-situ and in high time resolution, JDC has to cover a large field of view of 2π sr, for the desired energy range, in just a couple of seconds. An electrostatic analyzer within the sensor determines the energy per charge of such particles and a time-of-flight mass spectrometer measures their mass per charge. Constraints on weight and the radiation environment of Jupiter drive the design of the sensor: small and lightweight to allow extra shielding, but still large enough to accomplish measurements in the harsh radiation environment of Jupiter.

This work focuses on a new type of compact, electrostatic analyzer using spherical wedges and the start signal generation for the time-of-flight measurement using new venetian blind-type surfaces. Simulations on the electrostatic analyzer showed that the most promising design is a hybrid variant, using an inner shell with spherical wedges and a spheroidal outer shell. A prototype sensor was built and tested with successful results.

A reflectron-type time-of-flight cell measures the time it takes for a particle to pass a linear electric field. The time measurement has to be very accurate and requires that all ions enter the reflectron from the same start position. Commonly this is achieved with thin carbon foils of some nanometer thickness to provide a very accurate start position. Upon impact and after leaving a foil, ions generate secondary electrons that act as start signals for the time measurement. Foils require a substantial pre-acceleration of several kilovolts for the ions to penetrate the foil, thus increasing the size and mass of the instrument.

When incident ions are reflected at grazing angles from a surface, secondary electrons are released in the same way as with foils. To increase position accuracy during this reflection process, venetian blind-type start surfaces are investigated, where many smaller surfaces replace a large flat surface. The most promising sample was found to be micro pore optics, that were initially designed to focus gamma rays. In several experiments it could be shown that micro pore optics show good reflection properties when used as start surfaces in the time-of-flight measurement.

Both improvements allow a more compact and lightweight sensor that can be better shielded against the harsh radiation environment in Jupiter’s system. Jupiter hosts the strongest radiation environment in the solar system, that could kill an unprotected human thousand times over.

Place, publisher, year, edition, pages
Umeå: Umeå universitet , 2016. , 180+2 p.
Series
IRF Scientific Report, ISSN 0284-1703 ; 308
Keyword [en]
plasma instrumentation, time-of-flight, space, Jupiter, JUICE, PEP, JDC, start surface, charge fraction, the final frontier, accidental counts, chance counts, micro pore optics, spherical-wedge electrostatic analyzer
National Category
Fusion, Plasma and Space Physics
Research subject
Space and Plasma Physics; Physics
Identifiers
URN: urn:nbn:se:umu:diva-119112ISBN: 978-91-982951-2-2 (print)OAI: oai:DiVA.org:umu-119112DiVA: diva2:926416
Public defence
2016-06-01, Aulan, Rymdcampus 1, Kiruna, 14:00 (English)
Opponent
Supervisors
Projects
JUICE, PEP
Available from: 2016-05-11 Created: 2016-04-11 Last updated: 2016-06-02Bibliographically approved

Open Access in DiVA

fulltext(42628 kB)326 downloads
File information
File name FULLTEXT01.pdfFile size 42628 kBChecksum SHA-512
9f163ca712c308adb98c7bb616dddd2e5a68be805d31f41256c090311fa3c1d437b24c25d95ee52bb6f307e134ffc2f54a88a95df2cd669241ac420896e0a500
Type fulltextMimetype application/pdf
spikblad(69 kB)26 downloads
File information
File name SPIKBLAD01.pdfFile size 69 kBChecksum SHA-512
a008356be963d9a605bacba65f995583345f6342fe8486d718cb9aec63fd999cd75128e3769b77c48c672345fe63ed31dfe93dd26a2ea5f6be7b382fc4912a7a
Type spikbladMimetype application/pdf
errata(74 kB)7 downloads
File information
File name ERRATA01.pdfFile size 74 kBChecksum SHA-512
a554fe726116d75552ae0f11007f6a9879d518242f20cd5b86e396fb3c5e6f607288ef66ccfdeaa839c99848c0da9a57c36b8387d734f1606b731024c5a82b9a
Type errataMimetype application/pdf

Search in DiVA

By author/editor
Stude, Joan
By organisation
Department of Physics
Fusion, Plasma and Space Physics

Search outside of DiVA

GoogleGoogle Scholar
Total: 326 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 1797 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf