Model-based Assessment of Heat Pump Flexibility
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Solid State Physics. (Built Environment Energy Systems Group (BEESG))
2016 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Today's energy production is changing from scheduled to intermittent generation due to the increasing energy injection from renewable sources. This alteration requires flexibility in energy generation and demand. Electric heat pumps and thermal storages were found to have a large potential to provide demand flexibility which is analysed in this work. A three-fold method is set up to generate thermal load profiles, to simulate heat pump pools and to assess heat pump flexibility. The thermal profile generation based on a combination of physical and behavioural models is successfully validated against measurement data. A randomised system sizing procedure was implemented for the simulation of heat pump pools. The parameter randomisation yields correct seasonal performance factors, full load hours and average operation cycles per day compared to 87 monitored systems. The flexibility assessment analysis the electric load deviation of representative heat pump pool in response to 5 different on / off signals. The flexibility is induced by the capacity of thermal storages and analysed by four parameters. Generally, on signals are more powerful than off signals. A generic assessment by the ambient temperature yield that the flexibility is highest for heating days and the activated additional space heating storage: Superheating of the storage to the maximal temperature provides a flexible energy of more than 400 kWh per 100 heat pumps in a temperature range between -10 and +13 °C.

Place, publisher, year, edition, pages
2016. , 77 p.
Series
MSc ET
Keyword [en]
Heat pump pool model, Thermal storage, Stochastic building model, Flexibility
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:uu:diva-284083OAI: oai:DiVA.org:uu-284083DiVA: diva2:919753
External cooperation
Fraunhofer Institute of Solar Energy Systems, Freiburg
Educational program
Master Programme in Energy Technology
Presentation
via Adobe Connect (English)
Supervisors
Examiners
Available from: 2016-05-11 Created: 2016-04-14 Last updated: 2016-05-11Bibliographically approved

Open Access in DiVA

MSc_Report_Tobias_Wolf(4487 kB)545 downloads
File information
File name FULLTEXT01.pdfFile size 4487 kBChecksum SHA-512
7c2d8cbb42bd7442c1dae96a46bc15ca533de071b7d405a62adc83abca9c8ebe7d0bab385174a0a2e17d86a677c263a6439718e5ca4024a57186eb0cdc941cdd
Type fulltextMimetype application/pdf

By organisation
Solid State Physics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 545 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 555 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf