Geometric Misalignment Calibration and Detector Lag Effect Artifact Correction in a Cone-Beam Flat Panel micro-CT System for Small Animal Imaging
KTH, School of Technology and Health (STH).
2015 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

The cone-beam flat panel micro-CT is a high definition imaging system. It acquires projections of an object or animal to reconstruct a 3D image of its internal structure. The device is basically composed by a radiation tube and a detector panel, which are fixed to a gantry that rotates all around the test subject. The micro-CT system is affected by several imperfections and problems, that might lead to serious artifacts that deteriorate the quality of the reconstructed image. In particular, two issues have been discussed in the present work: the source-panel geometric misalignment and the detector lag effect. The first problem concerns the consequences of systems where the different elements are not perfectly aligned to each other. The second issue regards the residual signal, left in the detector's sensor after a projection acquisition, which affects the following frames with ghost images. Both these arguments have been investigated to describe their characteristics and behaviour in a typical acquisition protocol. Then two correction methods have been presented and tested on a real micro-CT device to verify their effectiveness in the artifacts compensation. In the end, a comparison between images before and after the corrections is provided and future prospects are discussed.

Place, publisher, year, edition, pages
2015. , 118 p.
Series
TRITA-STH, 2015:112
Keyword [en]
medical, engineering, imaging, CT, microCT, animal, calibration, misalignment, geometric, detector, lag effect, artifact, correction, cone-beam, flat panel
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-179873OAI: oai:DiVA.org:kth-179873DiVA: diva2:890787
Subject / course
Medical Engineering
Educational program
Master of Science - Medical Engineering
Supervisors
Examiners
Available from: 2016-01-11 Created: 2016-01-04 Last updated: 2016-01-11Bibliographically approved

Open Access in DiVA

fulltext(22273 kB)202 downloads
File information
File name FULLTEXT01.pdfFile size 22273 kBChecksum SHA-512
7f30ad6fe9515dca71fe0b2148d02cbf5e4ca4df97b69a45475e7622e49b9728b1bbd5c02f768fd35c4deb47b7edc40f57148872416460aff4d4e04125ef250a
Type fulltextMimetype application/pdf

By organisation
School of Technology and Health (STH)
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 202 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 763 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf