2015 (English)In: EJNMMI physics, ISSN 2197-7364, Vol. 2, no 1, 25Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners.

METHODS: 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR).

RESULTS: FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p < 0.001 for all). FSV based on (11)C-acetate and (15)O-water correlated highly (r = 0.99, slope = 1.03) with no significant difference between FSV estimates (p = 0.14).

CONCLUSIONS: FSV can be obtained automatically using dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation.

Place, publisher, year, edition, pages
2015. Vol. 2, no 1, 25
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-268064DOI: 10.1186/s40658-015-0133-0ISI: 000379208500025PubMedID: 26501826OAI: diva2:875833
Available from: 2015-12-02 Created: 2015-12-02 Last updated: 2016-08-10Bibliographically approved

Open Access in DiVA

fulltext(750 kB)16 downloads
File information
File name FULLTEXT01.pdfFile size 750 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Kero, TanjaÖrndahl, Lovisa HolmBjerner, TomasSörensen, Jens
By organisation
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 16 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 146 hits
ReferencesLink to record
Permanent link

Direct link