Cole Parameter Estimation from the Modulus of the Electrical Bioimpeadance for Assessment of Body Composition. A Full Spectroscopy Approach
University of Borås, School of Engineering. (Medical TexTTronics)
University of Borås, School of Engineering. (Medical TexTTronics)
2011 (English)In: Journal of Electrical Bioimpedance, ISSN 1891-5469, E-ISSN 1891-5469, Vol. 2, 72-78 p.Article in journal (Refereed)
Abstract [en]

Activities around applications of Electrical Bioimpedance Spectroscopy (EBIS) have proliferated in the past decade significantly. Most of these activities have been focused in the analysis of the EBIS measurements, which eventually might enable novel applications. In Body Composition Assessment (BCA), the most common analysis approach currently used in EBIS is based on the Cole function, which most often requires curve fitting. One of the most implemented approaches for obtaining the Cole parameters is performed in the impedance plane through the geometrical properties that the Cole function exhibit in such domain as depressed semi-circle. To fit the measured impedance data to a semi-circle in the impedance plane, obtaining the Cole parameters in an indirect and sequential manner has several drawbacks. Applying a Non-Linear Least Square (NLLS) iterative fitting on the spectroscopy measurement, obtains the Cole parameters considering the frequency information contained in the measurement. In this work, from experimental total right side EBIS measurements, the BCA parameters have been obtained to assess the amount and distribution of whole body fluids. The values for the BCA parameters have been obtained using values for the Cole parameters estimated with both approaches: circular fitting on the impedance plane and NLLS impedance-only fitting. The comparison of the values obtained for the BCA parameters with both methods confirms that the NLLS impedance-only is an effective alternative as Cole parameter estimation method in BCA from EBIS measurements. Using the modulus of the Cole function as the model for the fitting would eliminate the need for performing phase detection in the acquisition process, simplifying the hardware specifications of the measurement instrumentation when implementing a bioimpedance spectrometer.

Place, publisher, year, edition, pages
Universitetet i Oslo , 2011. Vol. 2, 72-78 p.
Keyword [en]
Textile-Enable Measurement Instrumentation, Textile-Electronics
National Category
Control Engineering Biomedical Laboratory Science/Technology
Research subject
Textiles and Fashion (General)
URN: urn:nbn:se:hb:diva-3185DOI: 10.5617/jeb.197Local ID: 2320/9430OAI: diva2:871282
Available from: 2015-11-13 Created: 2015-11-13

Open Access in DiVA

fulltext(419 kB)67 downloads
File information
File name FULLTEXT01.pdfFile size 419 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Buendia, RubenSeoane, Fernando
By organisation
School of Engineering
In the same journal
Journal of Electrical Bioimpedance
Control EngineeringBiomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 67 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 44 hits
ReferencesLink to record
Permanent link

Direct link