3D Scintillation Positioning Method in a Breast-specific Gamma Camera
KTH, School of Technology and Health (STH), Medical Engineering. (Medical Imaging)
2015 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

In modern clinical practice, gamma camera is one of the most important imaging modalities for tumour diagnosis. The standard technique uses scintillator-based gamma cameras equipped with parallel-hole collimator to detect the planar position of γ photon interaction (scintillation). However, the positioning is of insufficient resolution and linearity for breast imaging. With the aim to improve spatial resolution and positioning linearity, a new gamma camera configuration was described specifically for breast-imaging. This breast-specific gamma camera was supposed to have the following technical features: variable angle slant-hole collimator; double SiPM arrays readout at the front and back sides of the scintillator; diffusive reflectors at the edges around the scintillator. Because slant-hole collimator was used, a new 3D scintillation positioning method was introduced and tested. The setup of the gamma detector was created in a Monte Carlo simulation toolkit, and a library of a number of light distributions from known positions was acquired through optical simulation. Two library-based positioning algorithms, similarity comparison and maximum likelihood, were developed to estimate the 3D scintillation position by comparing the responses from simulated gamma interactions and the responses from library. Results indicated that the planar spatial resolution and positioning linearity estimated with this gamma detector setup and positioning algorithm was higher than the conventional gamma detectors. The depth-of-interaction estimation was also of high linearity and resolution. With the results presented, the gamma detector setup and positioning method is promising in future breast cancer diagnosis.

Place, publisher, year, edition, pages
2015. , 96 p.
Keyword [en]
gamma camera, breast imaging, monte carlo simulation, depth of interaction
National Category
Medical Engineering
URN: urn:nbn:se:kth:diva-176453OAI: diva2:867213
Subject / course
Medical Engineering
Educational program
Master of Science in Engineering - Medical Engineering
2015-06-11, 3-221, Alfred Nobels Allé 10, Huddinge, 10:00 (English)
Available from: 2015-11-05 Created: 2015-11-04 Last updated: 2015-11-05Bibliographically approved

Open Access in DiVA

fulltext(1706 kB)65 downloads
File information
File name FULLTEXT01.pdfFile size 1706 kBChecksum SHA-512
Type fulltextMimetype application/pdf

By organisation
Medical Engineering
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 65 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 56 hits
ReferencesLink to record
Permanent link

Direct link