Hybrid heating system for open-space office/laboratory
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.ORCID iD: 0000-0002-2822-0000
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2015 (English)In: Energy, Science and Technology 2015: Book of Abstracts. The energy conference for scientists and researchers / [ed] Karlsruher Institut für Technologie (KIT), Karlsruher, Germany: Karlsruhe, KIT , 2015, Vol. 1, 315-315 p.Conference paper, Poster (with or without abstract) (Refereed)
Abstract [en]

Open-space office/laboratory are quite common in Scandinavia and they are usually designed for multipurposework. There are office area where is possible to work standing up and in the same time to work at the desk. Forthis purpose a hybrid heating system made by electric convectors and panel radiators is investigated. Two stepresponse tests of the hybrid heating system are performed at the laboratory of Umeå University. The first test isexecuted during the week, disturbances from heat sources degrading the quality of the results. The second test isperformed during week-end. The error analysis shows a maximum discrepancies of +0.6 °C between measuredand simulated data. However, a thermal time constant of the room can be deducted and use it for controlling purposes.

Place, publisher, year, edition, pages
Karlsruher, Germany: Karlsruhe, KIT , 2015. Vol. 1, 315-315 p.
Keyword [en]
Open office, Hybrid heating system, Step response test, Error analysis
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:umu:diva-109889OAI: oai:DiVA.org:umu-109889DiVA: diva2:859736
Conference
EST, Energy Science Technology, International Conference & Exhibition, 20-22 May 2015, Karlsruhe, Germany
Available from: 2015-10-08 Created: 2015-10-08 Last updated: 2017-06-22Bibliographically approved
In thesis
1. Modelling and simulation of building components: thermal interaction between multilayer wall and hydronic radiator
Open this publication in new window or tab >>Modelling and simulation of building components: thermal interaction between multilayer wall and hydronic radiator
2016 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Background and Scope The scope of this thesis is to investigate the thermal behaviour of building components as hydronic radiator and multilayer walls subjected to dynamic conditions. The modelling and simulation of these building components provide information on how these components thermally interact among each other. The thermal interaction is fundamental to know how the energy is used in buildings. In particular, the thermal energy used in rooms can be expressed as the efficiencies for emission in a space heating system. This thesis analyzes the efficiencies for emission of a space heating system equipped with hydronic radiator for Swedish buildings by providing a comprehensive and detailed approach on this topic.

 

Methodology The methods used in this thesis are: experiment, modelling of multilayer wall and hydronic radiator, the dynamic simulation of the building and the efficiencies for emission of a space heating system. Here, the experiment, known as step response test, shows the heating up process of a hydronic radiator. The observation of the qualitative measurements suggests the most suitable technique of modelling the radiator known as transient modelling with multiple storage elements. The multilayer wall has been discretized both in space and time variable with a Finite Difference Method. Dynamic simulation of the building provides the efficiencies for emission of a space heating system.

 

Findings The experimental results show how the radiator performs the charging phase. The performance of the transient model is compared with lumped steady state models in terms of temperature of exhaust flow and total heat emitted. Results of the dynamic simulation show how buildings located in a Northern climate use the energy in a better way than Southern climates in Sweden. Heavy active thermal mass provides higher efficiencies for emission than light thermal mass. Radiators with connection pipes located on the same side react faster at the thermodynamic changing of the mass flow rate by providing higher efficiencies for emission than radiators with connection pipes located on the opposite side.

 

Conclusion and Outlook This thesis increases the knowledge about the modelling and simulation of hydronic radiators and multilayer walls. More research is needed on this topic to encompass modelling details of building components often ignored. The modelling and simulation of building components are the key to understand how building components thermally interact with each other. The thermal interaction among building components is a fundamental parameter for the assessment of efficiencies of emission of the space heating system. In the near future, the concept of efficiencies of emission can be implemented in National Building Code, therefore, this study provides guidelines on how to assess these efficiencies.

Place, publisher, year, edition, pages
Umeå: Umeå University, 2016. 39 p.
Keyword
Hydronic radiator, multilayer wall, efficiencies of emission
National Category
Building Technologies
Research subject
Systems Analysis; Technical Physics
Identifiers
urn:nbn:se:umu:diva-121201 (URN)978-91-7601-515-5 (ISBN)
Presentation
2016-06-15, MC413, MIT-huset, Umeå University, Umeå, 13:00 (English)
Opponent
Supervisors
Note

Advisors: Ronny Östin and Mohsen Soleimanni Mohseni, Department of Applied Physics and Electronics, Umeå University

Available from: 2016-05-30 Created: 2016-05-30 Last updated: 2016-06-03Bibliographically approved

Open Access in DiVA

fulltext(575 kB)95 downloads
File information
File name FULLTEXT01.pdfFile size 575 kBChecksum SHA-512
548e5036ea63e7636ea487589f6b312eae7ce63e5d91b1bdc056fb39e2ffad40a2ab90266da9d204467a65b783ba1dd21b6182c2955568f1bf906ab26fda680b
Type fulltextMimetype application/pdf

Other links

URLURL

Search in DiVA

By author/editor
Brembilla, ChristianSoleimani-Mohseni, MohsenOlofsson, Thomas
By organisation
Department of Applied Physics and Electronics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 95 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 477 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf