Undersökning av TRP tak med PIR isolering utan plastfolie
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.
2015 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Investigation of TRP-roof construction with PIR insulation without plastic film (English)
Abstract [sv]

Idag ligger fokus på energieffektivisering av byggnader. I och med detta ligger tung vikt på fuktsäkerhetsprojektering i konstruktioner som i sin tur måste vara lufttäta och diffusionstäta.

Kombinationen av svenska vinterperioder och övertrycket som uppstår inomhus medför att taken utsätts för stora påfrestningar. Luften inomhus innehåller alltid mer fukt än luften utomhus. Då fukt alltid strävar efter att jämna ut sig går den varma och fuktiga inomhusluften till utrymmen med lägre fukthalt eller lägre lufttryck. Det är bland annat av dessa anledningar man använder ångspärr i ytterväggar och takkonstruktioner.

Syftet med detta projekt är att genomföra en fuktteknisk bedömning för takkonstruktioner uppbyggda av TRP plåt, PIR isolering utan plastfolie. Anledningen till att bygga tak utan plastfolie är att sätta fuktfrågorna i fokus vid nybyggnadsprojekt samt att eftersträva skapandet av fuktsäkra och sunda konstruktioner.

För att analysera takkonstruktionen samt genomföra fukttekniska bedömningar har simuleringar av konstruktionen under olika förutsättningar i WUFI Pro 5.1. genomförts. Därefter har resultatet analyserats ur diffusions- och konvektionssynpunkt.

Resultaten visar inga större skillnader ur diffusionssynpunkt. Dock är skillnaderna mer uppenbara ur konvektionssynpunkt. Fuktmängden i konstruktionen utan plastfolie var betydligt större än konstruktion med plastfolie. Resultaten visar på att luftläckaget och fuktmängden har ett proportionellt förhållande med luftspaltbredden som bildas mellan PIR isoleringselementen. Detta gäller om ingen plastfolie används i konstruktionen.

Slutsatsen är att det råder en större risk för luftläckage hos takkonstruktionen utan plastfolie på grund av otätheter i skarvar och spalter. För att få en fuktsäker och sund konstruktion rekommenderar författarna att plastfolie används.

Abstract [en]

Nowadays there is a high focus on energy efficiency of buildings. Therefore, a lot of resources are dedicated to moisture management in order to ensure that constructions stay airproof and diffused. 

The combination of Swedish winter periods and the overpressure that occurs indoors means that the ceilings are subjected to the great stress. Indoor air contains more moisture than the air outdoors. As moisture is always striving to even out, the hot and humid indoor air moves to spaces with lower moisture content or lower air pressure. It is partly for these reasons why it is necessary to use a vapor barrier in the outer wall and roof construction.

The purpose of building roofs without plastic foil is to put moisture issues in focus for new construction projects, but also, seek to create moisture proof and healthy construction designs.

Further the goal of this project is to conduct a moisture technical assessment of roof structures built by TRP plate and PIR insulation without plastic film. Additionally, investigate if PIR-insulation can act as diffusion and convection protection.

In order to analyze the roof structure and conduct moisture technical assessments, the design has been simulated using WUFI Pro 5.1 during different conditions. The result has then been analyzed from diffusion and convection perspectives.

The results showed no major differences when compared from diffusion point of view. However, the differences are more obvious from convection perspective. The amount of moisture in the construction without plastic foil was considerably larger than the construction with a plastic foil. The results also showed that the air leakage and moisture amount has proportional ratio to the air gap width between the PIR-insulation elements. This is the case if no plastic foil used in the construction.

The conclusion is that there is a greater risk of air leakage in the roof construction without the plastic foil because of leaks in the joins or gaps. For a moisture-proof and healthy design, the authors recommend that a plastic foil should be used.

Place, publisher, year, edition, pages
2015. , 35 p.
Keyword [sv]
WUFI, plastfolie, luftläckage, konvektion, diffusion, PIR- isolering, inomhusluft, ångspärr, lufttäta, fuktsäker., WUFI, plastic foil, air leakage, diffusion, convection PIR- insulation, indoors, vapor, barrier, airproof, moisture-proof
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-174353OAI: oai:DiVA.org:kth-174353DiVA: diva2:859140
External cooperation
Northpower Stålhallar AB
Educational program
Bachelor of Science in Engineering - Constructional Engineering and Design
Supervisors
Examiners
Available from: 2015-10-08 Created: 2015-10-06 Last updated: 2015-10-08Bibliographically approved

Open Access in DiVA

fulltext(876 kB)259 downloads
File information
File name FULLTEXT01.pdfFile size 876 kBChecksum SHA-512
8f8b1fbf3aac5719d02b361ab953d6951a6f4e229a818d4d4505bb9bfae4dd42c077995c407bce098720f33d9fafdaaa4e7f3b2c9395a79efb7a169a5176a115
Type fulltextMimetype application/pdf

By organisation
Civil and Architectural Engineering
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 259 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 326 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf