Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energisimulering av byggnadertidigt i projekteringsfasen: En utvärdering av Energy Analysis som verktyg för hållbar byggnadsdesign
Karlstad University, Faculty of Health, Science and Technology (starting 2013).
2015 (Swedish)Independent thesis Basic level (professional degree), 15 credits / 22,5 HE creditsStudent thesisAlternative title
Energy simulation of buildings in an early design phase : An evaluation of Energy Analysis as a tool for sustainable building design (English)
Abstract [sv]

Dagens samhälle står idag inför en stor utmaning, nämligen att minska dess påverkan påmiljön. EU har satt upp riktlinjer mot en mer hållbar utveckling, vilket Sverige beslutat attfölja, där ett mål varit att energianvändningen 2020 ska ha minskat med 20 % jämfört med år2008. År 2021 införs krav på att alla nybyggnationer minst ska uppfylla näranollenergihuskrav.Detta medför ett större ansvar på projektörer att skapa underlag förenergieffektivare byggnader.Den tidiga designprocessen av byggnader kännetecknas av en initiativrik process där mångabeslut fattas på kort tid. De tidiga besluten som berör byggnadsutformningen har enbetydande roll för hur stora energibehov den färdiga produkten kommer att få. Energibehovetpåverkar både byggnadens livscykelkostnad och dess miljöpåverkan. Den här studien ärinriktad på energisimuleringar tidigt i projekteringsprocessen vars syfte är att skapadesigndrivande underlag till beslut rörande byggnadsutformning.Autodesk Revit har ett integrerat verktyg, Energy Analysis, som gör energisimuleringar avBIM-modellen i programmet. Verktyget är framtaget för att göra snabba energisimuleringarsom ska fungera som beslutsunderlag vid projektering mot hållbara byggnadsdesigner. Måletmed studien var att kartlägga beräkningarnas tillförlitlighet och resultatens användbarhet försvenska arkitekter. Utifrån en CAD-fil på ett hus från Klara arkitektbyrå gjordes simuleringari Energy Analysis som jämfördes med samma hus skapat Strusofts VIP-Energy.Resultaten visar att programmen redovisar olika utdata där vissa ej är jämförbara. Jämförelserav transmissionen i de båda programmen visar dock att beräkningsmotorn i Energy Analysisger rimliga resultat. Programmen räknar förhållandevis lika på solinstrålning genom fönster,dock finns det en svaghet hos Energy Analysis när de räknar på fönster med solskydd.Av resultaten dras en slutsats att Energy Analysis gör tillräckligt noggranna beräkningar föratt kunna användas tidigt i projekteringen. Verktyget behöver dock utvecklas och anpassa enversion för svenska förhållanden och normer för att det ska bli användbart i Sverige, vilketredovisas i ett förslag till produktutveckling i rapporten.

Abstract [en]

Today's society is facing a major challenge, namely to reduce its impact on the environment.The EU has set guidelines towards a more sustainable development, something in whichSweden has decided to comply; where the goal has been to minimize energy consumptionwith 20 % until 2020 compared to the consumption in 2008. In 2021, a requirement will beintroduced. It says that all new buildings in the EA must be “Nearly zero energy buildings” atleast. This implies a greater responsibility on the drafters to create the basis for energyefficient buildings.The early design process of buildings is characterized by a proactive process where manydecisions are made during a short amount time. Early decisions taken regarding the design ofa building affects its total need of energy when the house is put into use. Energy demandsaffects both the building life cycle cost and environmental impact. This study focuses onenergy simulations early in the design process that aims to create design driven basis fordecisions regarding building design.Autodesk Revit has an integrated tool, Energy Analysis, which allows energy simulations ofthe BIM model in the program. The tool is designed to make quick energy simulations thatcan provide a basis for planning the sustainable building designs. The goal of the study was toidentify the reliability of the calculations and usefulness of the results for Swedish architects.Based on a CAD file of a house from Klara arkitketbyrå(architectural firm) simulations weremade in Energy Analysis and then compared to simulations in StruSoft´s VIP Energy.The results show that the programs present different outputs in which some are notcomparable. Comparisons of conductivity in both of the programs show that the calculationengine in the Energy Analysis provides reasonable results. The programs estimate the solarradiation through the windows relatively similar; however, there is a weakness in the EnergyAnalysis as to how it calculates when the window is shaded by sunshields.By the results a conclusion has been drawn that the Energy Analysis allows sufficientlyaccurate calculations to be used early in the design process. The tool needs to be developedand customize a version for Swedish conditions and standards for it to be useful in Sweden, asreported in a suggestion for product development in the report.

Place, publisher, year, edition, pages
2015. , 53 p.
Keyword [en]
energy simulation, BIM, CAD, building design
Keyword [sv]
energisimulering, BIM, CAD, byggnadsdesign
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kau:diva-37993OAI: oai:DiVA.org:kau-37993DiVA: diva2:855398
Subject / course
Construction Engineering
Educational program
Study Programme in Building and Construction Engineering
Supervisors
Examiners
Available from: 2015-09-21 Created: 2015-09-21 Last updated: 2015-09-21Bibliographically approved

Open Access in DiVA

fulltext(1671 kB)145 downloads
File information
File name FULLTEXT01.pdfFile size 1671 kBChecksum SHA-512
7482561da561c6776262aec11a405035c73a03816dbbbd4c75d01d8b6498dc81fa222b20944654514e1bc2dffeb94aaeb1b2f77f592b5a4bfac5015dde08870c
Type fulltextMimetype application/pdf
Arkivfil(1653 kB)6 downloads
File information
File name FULLTEXT02.pdfFile size 1653 kBChecksum SHA-512
8dd6afb89b0d374d97dbb18ccf1d6ca848cdb6b979aae966a0ad05e391a12037f399676230f86252c84e0466457094d4bb9ed99ae0d6aae7df2a0ab4ead977c7
Type fulltextMimetype application/pdf

By organisation
Faculty of Health, Science and Technology (starting 2013)
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 151 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 432 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf