Analysis of the Response of AGATA Detectors at GSI
Show others and affiliations
2015 (English)In: CGS15 - CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2015, Vol. 93, 07007- p., 07007Conference paper (Refereed)
Abstract [en]

In 2012 and 2014 the gamma-ray tracking spectrometer AGATA was operated at the SIS/FRS facility at GSI in Darmstadt, Germany. The performance of the array is discussed, outlining some important aspects of the offline data processing and analysis. Relying on the data obtained from measurements with standard gamma-ray sources, a first estimate of the photopeak efficiency and peak-to-total (P/T) is presented.

Place, publisher, year, edition, pages
2015. Vol. 93, 07007- p., 07007
, EPJ Web of Conferences, ISSN 2100-014X ; 93
National Category
Physical Sciences
URN: urn:nbn:se:uu:diva-261485DOI: 10.1051/epjconf/20159307007ISI: 000358307500110ISBN: 978-2-7598-1794-8OAI: diva2:850525
15th International Symposium on Capture Gamma-Ray Spectroscopy and Related Topics (CGS), AUG 25-29, 2014, Dresden, GERMANY
Available from: 2015-09-01 Created: 2015-09-01 Last updated: 2015-09-01Bibliographically approved

Open Access in DiVA

fulltext(470 kB)15 downloads
File information
File name FULLTEXT01.pdfFile size 470 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Nyberg, Johan
By organisation
Nuclear Physics
Physical Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 15 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 158 hits
ReferencesLink to record
Permanent link

Direct link