Correlation of a FE-model of a truck heat exchanger with EMA
Blekinge Institute of Technology, School of Engineering, Department of Mechanical Engineering.
2005 (English)Independent thesis Advanced level (degree of Master (One Year))Student thesis
Abstract [en]

A simplified FE-model of the subcomponent of the Charge air cooler – core is modelled using homogenisation technique. Modal testing was performed on the physical model of the same. On comparing the resonance frequencies of the test data (reference result) with FE-model data, the FE-model is reconciled and correlated.

Place, publisher, year, edition, pages
2005. , 64 p.
Keyword [en]
FEA, CAC-core, Homogenisation, EMA, MIMO, Resonance frequency, Mode shapes, Correlation.
National Category
Signal Processing Mechanical Engineering
URN: urn:nbn:se:bth-2795Local ID: diva2:830089
+46-(0)73 657 38 57Available from: 2015-04-22 Created: 2005-05-26 Last updated: 2015-06-30Bibliographically approved