Performance Evaluation of Different PV-Array Configurations under Weak Light Conditions and Partial Shadings
Dalarna University, School of Technology and Business Studies, Energy and Environmental Technology.
2012 (English)Independent thesis Advanced level (degree of Master (One Year)), 12 credits / 18 HE creditsStudent thesis
Abstract [en]

The paper analyses empirical performance data of five commercial PV-plants in Germany. The purpose was on one side to investigate the weak light performance of the different PV-modules used. On the other hand it was to quantify and compare the shading losses of different PV-array configurations. The importance of this study relies on the fact that even if the behavior under weak light conditions or the shading losses might seem to be a relatively small percentage of the total yearly output; in projects where a performance guarantee is given, these variation can make the difference between meeting or not the conditions.When analyzing the data, a high dispersion was found. To reduce the optical losses and spectral effects, a series of data filters were applied based on the angle of incidence and absolute Air Mass. To compensate for the temperature effects and translate the values to STC (25°C), five different methods were assessed. At the end, the Procedure 2 of IEC 60891 was selected due to its relative simplicity, usage of mostly standard parameters found in datasheets, good accuracy even with missing values, and its potential to improve the results when the complete set of inputs is available.After analyzing the data, the weak light performance of the modules did not show a clear superiority of a certain technology or technology group over the others. Moreover, the uncertainties in the measurements restrictive the conclusiveness of the results.In the partial shading analysis, the landscape mounting of mc-Si PV-modules in free-field showed a significantly better performance than the portrait one. The cross-table string using CIGS modules did not proved the benefits expected and performed actually poorer than a regular one-string-per-table layout. Parallel substrings with CdTe showed a proper functioning and relatively low losses. Among the two product generations of CdTe analyzed, none showed a significantly better performance under partial shadings.

Place, publisher, year, edition, pages
2012. , 87 p.
National Category
Energy Systems
URN: urn:nbn:se:du-16428OAI: diva2:764930
2012-10-25, Borlänge, 21:37 (English)
Available from: 2014-11-24 Created: 2014-11-20 Last updated: 2014-11-24Bibliographically approved

Open Access in DiVA

fulltext(15287 kB)781 downloads
File information
File name FULLTEXT01.pdfFile size 15287 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Hernandez Velasco, Marco
By organisation
Energy and Environmental Technology
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 781 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 145 hits
ReferencesLink to record
Permanent link

Direct link