Change search
ReferencesLink to record
Permanent link

Direct link
Advanced Mueller Matrix Imaging Ellipsometry: Silicon Strain Imaging, Visualisation of Collagen Fibre 3-D Orientation & Development of a Mueller Matrix Imaging Microscope
Norwegian University of Science and Technology, Faculty of Natural Sciences and Technology, Department of Physics.
2014 (English)MasteroppgaveStudent thesis
Abstract [en]

A custom built near-infra-red (NIR) Mueller matrix imaging ellipsometer (MMI) based on ferroelectric liquid crystals (FLCs) and waveplates (WPs) is described in detail. The instrument is used to perform strain-induced birefringence imaging of crystalline silicon, and visualise the 3-D orientation of collagen fibres expressing linear retardance. The development of a spectroscopic Mueller matrix imaging microscope ellipsometer (µMMI) is presented. Preliminary verification indicate that the constructed µMMI works as expected. The theory behind Mueller matrix ellipsometry is outlined, including the description of polarised light, and its representation by the Mueller-Stokes formalism. Detailed analysis of the Mueller matrix, encompassing both the forward polar and the differential decomposition, is presented. These techniques are used in the study of both organic and in-organic samples. Photoelastic theory is briefly discussed in order to explain the phenomena of birefringence in strained silicon crystals, and a simple model was developed in order to estimate the maximum shear-stress. Vertical cross-sections of bi-crystal silicon separated by near-coincident site lattice grain boundaries $\Sigma9$ and $\Sigma27a$ ingots were studied using the custom built near infra-red MMI at 1300 nm. The obtained images were decomposed using the forward polar decomposition. The resulting optical properties were used to map the internal shear-stress of the samples. The shear-stress was found to be in the range of 2.5 MPa to 5 MPa. Further studies are proposed in order to verify this technique. Chicken tendon is imaged at 940 nm with different incidence angles (0 deg and +/-30 deg) using the custom built MMI. The differential decomposed Mueller matrix measurements were used to calculate the 3-D directional orientation of the collagen fibres. Validation of the obtained 3-D directional orientation was done by comparing the results with second-harmonic generation (SHG) images. The two methods were found to be in good agreement. Development of an optimal broadband spectroscopic Mueller matrix imaging system to work in the range 550nm to 1150 nm is described. A design similar to the earlier presented MMI based on FLCs and WPs was chosen. The concept of genetic algorithms is introduced and utilised in order to improve on the design. Realisation of the instrument is documented from the choice of components, characterisation, re-optimisation of the design, and lastly, building and verifying the instrument.

Place, publisher, year, edition, pages
Institutt for fysikk , 2014. , 156 p.
URN: urn:nbn:no:ntnu:diva-27158Local ID: ntnudaim:8548OAI: diva2:759720
Available from: 2014-10-30 Created: 2014-10-30 Last updated: 2014-10-30Bibliographically approved

Open Access in DiVA

fulltext(33992 kB)563 downloads
File information
File name FULLTEXT01.pdfFile size 33992 kBChecksum SHA-512
Type fulltextMimetype application/pdf
cover(775 kB)14 downloads
File information
File name COVER01.pdfFile size 775 kBChecksum SHA-512
Type coverMimetype application/pdf

By organisation
Department of Physics

Search outside of DiVA

GoogleGoogle Scholar
Total: 563 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 132 hits
ReferencesLink to record
Permanent link

Direct link