Change search
ReferencesLink to record
Permanent link

Direct link
Stabilization of an optical frequency comb to an external cavity
Umeå University, Faculty of Science and Technology, Department of Physics. (Optical Frequency Comb Spectroscopy Group)
2014 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

The subject of this master's thesis is stabilizing a frequency comb laser to an external cavity using a couple of servo controllers. The aim of the project was to build a pair of servo controllers, replacing parts of the existing commercial and proprietary solution already in use. The system under control is an optical frequency comb, which is locked to an external cavity and is used for trace gas detection and spectroscopy. The comb is a broadband light source and needs to be locked to the external cavity in order to achieve maximum transmission through the cavity. The goal was to replace two of the original controllers and try to improve the locking capabilities of the system. The controllers were also supposed to be customizable and for that reason the control system with all its components was built on breadboards and confined in an aluminium box.

Control circuits were built for the purpose, one for controlling the comb offset frequency by modulating the pump diode current, the other for controlling the repetition rate of the comb laser by altering the length of the laser cavity using a piezo-electric transducer (PZT). A commercial and proprietary servo controller was also in the system, controlling an intra-cavity electro-optic modulator. It was kept for controlling the higher frequency region, for which the PZT no longer worked.

In order to simulate and design the system, Matlab was used with functions described by both theoretically and experimentally obtained mathematical equations. The controllers were tested thoroughly in order to make sure they acted according to the intended design, before they were tested with the laser. After an initial lock was obtained, the controllers were optimized further using both experimental and theoretical methods until the lock was optimized and the transmission through the cavity was maximized. The error signals that were used for controlling the system were monitored with both an oscilloscope and a spectrum analyser, the latter producing a spectrum with the power ratio plotted versus frequency. The transmission intensity through the cavity was measured when a good lock had been achieved and the results were analysed by applying a Fourier transform to the measured data. This was done with both the old controllers and the new controllers and the resulting plots were compared. Analysis showed that the new control system yielded a transmission signal with a slightly reduced noise level compared to the signal resulting from using the old controllers. The results from the spectrum analyser also showed slightly reduced error signals for the new controllers compared to those of the old controllers.

When summarising this work it can be concluded that the goals set up at the start were achieved with results living up to the expectations. The results also verified that such a control system can be built for locking an optical frequency comb to an external cavity with simple and rather cheap components and with good results.

Place, publisher, year, edition, pages
2014. , 48 p.
National Category
Control Engineering Atom and Molecular Physics and Optics
URN: urn:nbn:se:umu:diva-93439OAI: diva2:748853
Subject / course
Examensarbete i teknisk fysik
Educational program
Master of Science Programme in Engineering Physics
2014-08-29, Universitetsklubben, Umeå, 14:00 (English)
Available from: 2014-09-23 Created: 2014-09-22 Last updated: 2014-09-23Bibliographically approved

Open Access in DiVA

Thesis_Olof_Rydberg(4443 kB)261 downloads
File information
File name FULLTEXT01.pdfFile size 4443 kBChecksum SHA-512
Type fulltextMimetype application/pdf

By organisation
Department of Physics
Control EngineeringAtom and Molecular Physics and Optics

Search outside of DiVA

GoogleGoogle Scholar
Total: 261 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 871 hits
ReferencesLink to record
Permanent link

Direct link