Connection Between Critical Stress and Hydrogen Content for SDSS under Cathodic Protection
Norwegian University of Science and Technology, Faculty of Natural Sciences and Technology, Department of Materials Science and Engineering.
2014 (English)MasteroppgaveStudent thesis
Abstract [en]

In recent years Super Duplex Stainless Steel (SDSS) installed subsea with cathodic protection has failed during service. The failures have been due to Hydrogen Induced Stress Cracking (HISC). The effect from different protection potentials and hydrogen content has been investigated in regarding HISC susceptibility for a Hot Isostatically Pressed (HIP) SDSS according to UNS S32550. Pre-charging has been done in a 2:1 Glycerol – H3PO4 electrolyte at 120°C, while in-situ testing has been done in synthetic seawater (3.5% NaCl) at room temperature. Protection potentials have been varied from -1050mVAg/AgCl to -800mVAg/AgCl. Testing has been done in a small test-jig incorporating a light microscope for crack and microstructural surveillance of the samples. Non-notched and notched samples have been tested. The non-notched samples tested showed to be too ductile for the test-jig, thus only the -1050mVAg/AgCl sample fractured with a fracture strength of 136±0% of yield strength (YS). There was seen a trend for surface cracks to grow in size for more negative protection potentials. All the notched samples fractured, giving the following results 136±0%, 137.3±1.9%, 144±0%, 148±0% and 140±0% of YS for the -1050mVAg/AgCl, -1000mVAg/AgCl, -950mVAg/AgCl, -900mVAg/AgCl and -800mVAg/AgCl samples respectively. A notched sampled tested in air fractured at 161% of YS. The same trend for surface cracks growing in size for more negative potentials, as seen for the non-notched samples, was also seen for the notched samples. All the samples suffered from HISC, with all samples showing high fracture strengths. A hydrogen content of 13.40ppm showed to be sufficient for promoting HISC. The -800mVAg/AgCl samples suffered from HISC, concluding that this will not be a safe potential

Place, publisher, year, edition, pages
Institutt for produktutvikling og materialer , 2014. , 81 p.
URN: urn:nbn:no:ntnu:diva-26211Local ID: ntnudaim:11953OAI: diva2:745632
Available from: 2014-09-10 Created: 2014-09-10 Last updated: 2014-09-10Bibliographically approved

Open Access in DiVA

fulltext(6326 kB)530 downloads
File information
File name FULLTEXT01.pdfFile size 6326 kBChecksum SHA-512
Type fulltextMimetype application/pdf
cover(184 kB)0 downloads
File information
File name COVER01.pdfFile size 184 kBChecksum SHA-512
Type coverMimetype application/pdf

By organisation
Department of Materials Science and Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 530 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 45 hits
ReferencesLink to record
Permanent link

Direct link