Frequency Control: Optimal distribution of FCR-N in real-time
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity.
2014 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Frequency control systems are used to keep the grid frequency at the nominal value of 50.00 Hz. Vattenfall employ hydropower plants for this purpose as they can easily adapt their production to counteract frequency deviations.

This master thesis focuses on trying to improve Vattenfall’s mechanism to provide FCR-N (Frequency Containment Reserve in Normal operation) for primary frequency control, i.e. the turbine governor. The efforts are made to operate the plants more efficiently, decreasing distribution losses and thus increasing the profits.

The current control system was modelled in MATLAB’s simulation tool Simulink to understand its complexity and to be used as base for comparison. Then a new model was developed based on the idea to introduce a global governor for the frequency control in each plant which controls the input signal to the individual turbine governors of each unit. OPT-data (tabulated data indicating how to operate a plant at the highest possible efficiency) was used to determine how to optimally distribute the FCR-N among the active units in a plant in real-time.

The conclusions which can be drawn from this master thesis are that it is possible to make a more optimal distribution of FCR-N in real-time. However, it has not been possible to make a good comparison between the two models and the results regarding the profits which can be made by introducing this new type of governor are therefore inconclusive.

It is of crucial importance to make a better match of the regulating strengths of the two models in order to perform the comparison. Improving the parameter values for the proportional and integral gains of the individual controllers and the precision of the OPT-table lookups may further improve the new model and also make it possible to perform a valid comparison between the two models.

Place, publisher, year, edition, pages
2014. , 62 p.
Series
UPTEC F, ISSN 1401-5757 ; 14033
Keyword [en]
Frequency control, FCR-N, Hydropower, Optimisation, Turbine governor
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:uu:diva-230897OAI: oai:DiVA.org:uu-230897DiVA: diva2:742392
External cooperation
Vattenfall Vattenkraft AB
Supervisors
Examiners
Available from: 2014-09-01 Created: 2014-09-01 Last updated: 2014-09-01Bibliographically approved

Open Access in DiVA

fulltext(1884 kB)247 downloads
File information
File name FULLTEXT01.pdfFile size 1884 kBChecksum SHA-512
9be915074c4f59f001eddf27ee16fb1dc501261025ec23cf0ffebacb8d1c871a412d86cdb1d0732c3ed83d65d4f18a5e38c28eeb93249e00d8ad2b10861b766e
Type fulltextMimetype application/pdf

By organisation
Electricity
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 247 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1047 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf