Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Smart förpackning för transport av temperaturkänsliga produkter
KTH, School of Industrial Engineering and Management (ITM), Energy Technology.
KTH, School of Industrial Engineering and Management (ITM), Energy Technology.
2014 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Smart Packaging for Transport of Temperature Sensitive Products (English)
Abstract [sv]

Vid transport av temperaturkänsliga produkter krävs en förpackning som klarar av att hålla temperaturen inom ett visst intervall så att innehållet inte skadas. Omgivningstemperaturen kan variera mycket under en transport och det är viktigt att förpackning kan kyla passivt utan att påverkas för mycket av omgivningen. Ett typiskt användningsområde för denna typ av förpackningar är inom sjukvård för transport av läkemedel, organ och andra biologiska produkter.

Problemet som denna rapport behandlar är att ta fram en sådan förpackning för hingstsperma som skulle kunna skickas med posten. Sperman behövde först kylas ned från rumstemperatur till 5°C under tio timmar innan den skulle hållas vid denna temperatur i ytterligare 24 timmar. För att lösa detta användes en kombination av isolering och fasomvandlingsmaterial vars egenskap att lagra energi gör att en konstant temperatur kan hållas under en längre tid. Med hjälp av värmeöverföringsberäkningar kunde sedan en uppskattning för temperaturförloppet under 34 timmar tas fram. Detta blev grunden till dimensioneringen av en prototyp som testades tre gånger under olika omständigheter.

Resultatet från testerna gav en skillnad på ca ±2°C i lagrings temperatur mot målvärdet på 5°C och en kylningshastighet som var ca 1-3 timmar för snabb vilket gjorde att förpackningen inte uppnådde alla målen men den var tillräckligt liten för att kunna skickas med posten. Då kylningen inte sker snabbare än 20 minuter och vid temperaturer kring 5-8°C bör lådan enligt litteraturstudien klara sig i scenarion liknande det som testats.

För att validera förpackningen krävs ytterligare tester för att se om förpackningen klarar t.ex. ett vinterscenario och för att beräkna fram rätt mängd packning.

Abstract [en]

To avoid damage during the transportation of temperature sensitive products a package that can hold the temperature within a certain range is required. The ambient temperature can vary greatly during a journey and it is important that the package can cool passively without being influenced too much by the environment. A typical application for this type of packages is in healthcare for the transportation of medicine, organs and other biological products.

The problem that this report addresses is to develop such a package for stallion semen that can be sent with PostNord AB. The sperm needed to first be cooled from room temperature to 5°C during ten hours before it should be held at this temperature for another 24 hours. To solve this, a combination of insulation and phase change material, which has the capacity to store energy that enables a constant temperature to be maintained for a long time, was used. The temperature variations during a 34 hours span could then be estimated using heat transfer calculations. This became the base for the design of a prototype that was tested three times under different circumstances.

The results from the tests yielded a difference of about ± 2°C storage temperature to the target value of 5°C and a cooling rate that was 1-3 hours too fast which means that the package did not achieve all the goals but the package was small enough to be sent with postal service. The cooling was slower than 20 minutes and the temperatures after that was around 5-8°C, which means that the package should according to the literature study cope in scenarios similar to the ones tested.

To validate the package additional tests is required to know if the package can handle a winter scenario for example and to calculate the correct amount of packing.

Place, publisher, year, edition, pages
2014.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-148080OAI: oai:DiVA.org:kth-148080DiVA: diva2:735269
Available from: 2014-08-21 Created: 2014-07-21 Last updated: 2014-08-21Bibliographically approved

Open Access in DiVA

fulltext(1627 kB)211 downloads
File information
File name FULLTEXT01.pdfFile size 1627 kBChecksum SHA-512
cd0f159ddba8279095f09a94f4090030b6466d9eaab92a58136f763a8f07cf815bd6fdd9e88acd84444ac2ba9b61cc4d2c8720c323d7b2ed0d1c82070896b047
Type fulltextMimetype application/pdf

By organisation
Energy Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 211 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 171 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf