Performance Indicator Analysis as a Basis for Process Optimization and Energy Efficiency in Municipal Wastewater Treatment Plants
Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology.
2014 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Nyckeltalsanalys som underlag för processoptimering och energieffektivisering i kommunala avloppsvattenreningsverk (Swedish)
Abstract [en]

The aim of this Master Thesis was to calculate and visualize performance indicators for the secondary treatment step in municipal wastewater treatment plants. Performance indicators are a valuable tool to communicate process conditions and energy efficiency to both management teams and operators of the plant. Performance indicators should be as few as possible, clearly defined, easily measurable, verifiable and easy to understand.

Performance indicators have been calculated based on data from existing wastewater treatment plants and qualified estimates when insufficient data was available. These performance indicators were then evaluated and narrowed down to a few key indicators, related to process performance and energy usage. Performance indicators for the secondary treatment step were calculated for four municipal wastewater treatment plants operating three different process configurations of the activated-sludge technology; Sternö wastewater treatment plant (Sweden) using a conventional activated-sludge technology, Ronneby wastewater treatment plant (Sweden) using a ring-shaped activated-sludge technology called oxidation ditch, Headingley wastewater treatment plant (Canada) and Kimmswick wastewater treatment plant (USA), both of which use sequencing batch reactor (SBR) activated-sludge technology. Literature reviews, interviews and process data formed the basis of the Master Thesis. The secondary treatment was studied in all the wastewater treatment plants. Performance indicators were calculated, to the extent it was possible, for this step in the treatment process.

The results showed that all the wastewater treatments plants, studied in this master thesis, were well below regulatory requirements of effluent concentrations of organic matter and nutrients. This gap between legislated requirements and performance provides an opportunity for improving energy efficiency and maintaining discharge requirements. The removal of organic matter was consistently high at all wastewater treatment plants studied but the removal of nitrogen was slightly lower during the colder months. The results further showed that the discharge of nitrogen from wastewater treatment plants is the largest stress on the recipient.

Data regarding the energy usage was almost nonexistent and energy for aeration was therefore calculated when possible since it is aeration that accounts for the largest fraction of energy usage in a wastewater treatment plant. Sternö wastewater-treatment plant proved to be more energy efficient than Rustorp wastewater treatment plant.

Place, publisher, year, edition, pages
2014. , 76 p.
Series
UPTEC W, ISSN 1401-5765 ; 14008
Keyword [en]
Performance indicators, wastewater treatment, process performance, energy efficiency, secondary treatment
Keyword [sv]
Nyckeltal, avloppsvattenrening, processprestanda, energieffektivisering, biologisk rening
National Category
Water Treatment
Identifiers
URN: urn:nbn:se:uu:diva-218094OAI: oai:DiVA.org:uu-218094DiVA: diva2:694836
External cooperation
ÅF, Xylem
Educational program
Master Programme in Environmental and Water Engineering
Examiners
Available from: 2014-02-11 Created: 2014-02-07 Last updated: 2014-02-11Bibliographically approved

Open Access in DiVA

fulltext(724 kB)859 downloads
File information
File name FULLTEXT01.pdfFile size 724 kBChecksum SHA-512
d9adb9d04080caa90eca698f9d2bf439dc3766627242455a0fa22e710dd85a7551acdee05e5e7f6489657fa6b65af3c226fb5aca9e2aae9a452ea53e0d2daea8
Type fulltextMimetype application/pdf

By organisation
Department of Information Technology
Water Treatment

Search outside of DiVA

GoogleGoogle Scholar
Total: 859 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 756 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf