Flödesoptimering av bergvärmepumpar: Experimentell studie av köldbärarflödetsinverkan på systemets värmefaktor
KTH, School of Architecture and the Built Environment (ABE), Sustainable development, Environmental science and Engineering, Industrial Ecology.
2013 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Sammanfattning

Denna studie har gått ut på att undersöka hur köldbärar ödet påverkar värmepumpens

och systemets värmefaktor samt föreslå hur flödet kan optimeras. En kopplingsprincip som tillåter att flödet genom värmepumpens förångare är lägre än flödet genom borrhålen har utvärderats. Köldbärarflödet fanns ha en avgörande betydelse för värmepumpens värmefaktor och vid de utförda experimenten ökade värmefaktorn näst intill linjärt med  flödet. Tidigare forskning visar samma sak men att kurvan för värmefaktorn planar ut vid ytterligare höjning av köldbärarflödet. Beräknas istället systemets värmefaktor, där effekt för cirkulationspumpar räknas med, så existerar en punkt där en ytterligare höjning av köldbärarflödet ger en försämring av värmefaktorn på grund av ökad pumpeffekt. Inga resultat i studien tyder på att det skulle finnas en nytta av att ha lägre flöde genom förångaren än genom borrhålen. Istället ökade systemets värmefaktor vid sänkning av borrhålsflödena eftersom pumpeffekten kraftigt reducerades. Frågeställningen kommer att fortsätta utredas med en utförlig experimentserie.

Abstract [en]

Abstract

The aim of this study has been to investigate the impact of the secondary fluid flow(the brine) on the coeffcient of performance for both the heat pump unit and the entire system. A by-pass on the evaporator side that enables the flow through the evaporator to be lower than the flow through the boreholes has been evaluated. Increasing the secondary fluid flow through the evaporator was found to increase the heat pump units coeffcient of performance and the relation was found to be almost linear. Previous research has shown the same result but the rate of increase in the coeffcient of performance is decreasing with higher fluid flow. If the systems coeffcient of performance is calculated instead, which means taking power for the brine pump into account, a maximum point exists from where a further increasing of the brine flow would decrease the systems coeffcient of performance because of increased pumping power. No results in this study shows any benefit of running the system with a lower flow through the evaporator than through the boreholes. Instead the systems coefficient of performance was found to increase with a lower borehole flow because of reduced pumping power. This study will be followed by an extensive series of experiments.

 

Place, publisher, year, edition, pages
2013. , 36 p.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-140416OAI: oai:DiVA.org:kth-140416DiVA: diva2:690338
Educational program
Master of Science in Engineering - Energy and Environment
Supervisors
Examiners
Available from: 2014-01-23 Created: 2014-01-23 Last updated: 2014-01-23

Open Access in DiVA

fulltext(5134 kB)982 downloads
File information
File name FULLTEXT02.pdfFile size 5134 kBChecksum SHA-512
2d3c19ae2b84dee2ba9567f92e7c8f73e85cfd509a1209f7699b2746184cd5d0cb77cb66a930ae08c96540c990d1cd70cd3c8fa33b29a3abccc3106122d043b8
Type fulltextMimetype application/pdf

By organisation
Industrial Ecology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 982 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 329 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf