Change search
ReferencesLink to record
Permanent link

Direct link
Analysis of dynamical behaviour of the boiler room at Mechanical Engineering Faculty in Sarajevo in standard exploitation conditions.
Norwegian University of Science and Technology, Faculty of Engineering Science and Technology, Department of Energy and Process Engineering.
2013 (English)MasteroppgaveStudent thesis
Abstract [en]

ynamical analysis of the boiler room behaviour will be conducted by using state of the art software packages and available libraries for modelling and simulation of the HVAC systems. Mathematical model for transient analysis of the one dimensional fluid flow in pipes will be presented, and special attention will be given to modelling of the heating equipment such as: boiler, pumps, valves and fittings as well as the standard control elements of the heating systems. Object oriented symbolic Modelica language for industrial applications will be used within Dymola software environment with extensive utilisation of the Buildings library* for HVAC components modelling, developed by Simulation and Research group at Lawrence Berkeley National Laboratory ( Consumption side is not the primary subject of the current work and will be modelled as a simplified object/volume which is heated uniformly. Consumption side modelling will take into consideration the thermal capacity of the building as well as the thermal conductivity which will cover transmission and ventilation losses. Simplified model will be realised as a combination of measurements data reading and Finite Volume Model (FVM) of the Mechanical Engineering building. Fine tuning of the consumption side model will be done by using linear regression method. Numerical results of the boiler room model as well as the simplified consumption side model will be verified by comparison with available measurements data for predefined month in 2012/2013 heating season. Available data will be readings from hourly measurements of supply and return water temperatures from the boiler room, outside temperatures, boiler gas consumption and representative room temperature readings. Special attention will be given to highly transient situations, like after weekend days or similar.

Place, publisher, year, edition, pages
Institutt for energi- og prosessteknikk , 2013. , 86 p.
URN: urn:nbn:no:ntnu:diva-23505Local ID: ntnudaim:10224OAI: diva2:665417
Available from: 2013-11-19 Created: 2013-11-19 Last updated: 2013-11-19Bibliographically approved

Open Access in DiVA

fulltext(2721 kB)829 downloads
File information
File name FULLTEXT01.pdfFile size 2721 kBChecksum SHA-512
Type fulltextMimetype application/pdf
cover(184 kB)11 downloads
File information
File name COVER01.pdfFile size 184 kBChecksum SHA-512
Type coverMimetype application/pdf
attachment(2325 kB)43 downloads
File information
File name ATTACHMENT01.zipFile size 2325 kBChecksum SHA-512
Type attachmentMimetype application/zip

By organisation
Department of Energy and Process Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 829 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 266 hits