Optimization in CT: Evaluation of dose saving potential in a thorax-abdomen/pelvis protocol using iterative reconstruction techniques
Norwegian University of Science and Technology, Faculty of Natural Sciences and Technology, Department of Physics.
2013 (English)MasteroppgaveStudent thesis
Abstract [en]

The use of computed tomography (CT) has increased dramatically during the last two decades and contributes today to 80% of the estimated population dose caused by radiological examinations. Recent publications have shown an increased incidence of cancer caused by the irradiation from CT examinations and has led to increased dose awareness. In this study the dose saving potential for a thorax-abdomen/pelvis protocol on a Siemens SOMATOM Definition AS + (Siemens, Germany) was investigated. The main aim was to reduce the dose to the patient while maintaining similar image quality as the current scan protocol. Alternative reconstruction filters and using iterative techniques where applied to lower dose scans of a Catphan 600 phantom (Siemens Germany). Physical and objective image quality parameters, in this case the spatial resolution, noise and noise power spectrum (NPS) curves were measured in the lower dose scans of Catphan 600 and compared to the spatial resolution, noise and NPS measured in the current scan protocol. The parameter settings resulting in similar objective image quality where applied to scans of an anthropomorphic phantom. Signal to noise ratio (SNR) and contrast to noise ratio (CNR) where calculated and compared to SNR and CNR of the current scan protocol. The final best lower dose alternatives where presented for experienced radiologists for subjective evaluation. Physical image quality parameters such as spatial resolution, noise level, SNR and CNR were found to be maintained down at 50% dose level. However, the NPS curves revealed some minor shift in spatial distribution of the noise towards coarser graininess at the highest iterative strengths. The experienced thorax radiologist qualified all lower dose alternatives presented as diagnostically acceptable. The experienced gastro radiologist evaluated the scans reconstructed with a higher iterative level than 2 as blotchy and not diagnostically suitable. The observed blotchiness may have a correlation with the minor shift in NPS curves. In conclusion, a dose level of 75% (i.e. 25% lower dose than the current scan protocol) using higher iterative strength was found to be diagnostically acceptable and can be further explored on patients.

Place, publisher, year, edition, pages
Institutt for fysikk , 2013. , 75 p.
URN: urn:nbn:no:ntnu:diva-22444Local ID: ntnudaim:9957OAI: diva2:649688
Available from: 2013-09-19 Created: 2013-09-19 Last updated: 2013-09-19Bibliographically approved

Open Access in DiVA

fulltext(2984 kB)1115 downloads
File information
File name FULLTEXT01.pdfFile size 2984 kBChecksum SHA-512
Type fulltextMimetype application/pdf
cover(184 kB)8 downloads
File information
File name COVER01.pdfFile size 184 kBChecksum SHA-512
Type coverMimetype application/pdf

By organisation
Department of Physics

Search outside of DiVA

GoogleGoogle Scholar
Total: 1115 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 71 hits
ReferencesLink to record
Permanent link

Direct link