Change search
ReferencesLink to record
Permanent link

Direct link
AC-tap i MgB2-superleder: Effekt av simulert slaglende
Norwegian University of Science and Technology, Faculty of Information Technology, Mathematics and Electrical Engineering, Department of Electrical Power Engineering.
2013 (English)MasteroppgaveStudent thesis
Abstract [en]

Superconductive materials can conduct DC currents without energy losses when cooled down below their critical temperature. However, under AC conditions, energy losses appear in the superconductor. In 2001 the new and inexpensive superconductor MgB2 entered the market. Currently this conductor is used in DC applications such as MRI, but before implementing the use of MgB2 in AC applications more research has to be carried out. The basic questions are how large are the AC losses, in what way do they depend on magnetic field, current and temperature, and can they be reduced to a level acceptable for commercial use? This Master?s thesis is a part of a larger work at NTNU/SINTEF. In earlier projects calorimetric AC loss measurements have been performed on an MgB2 round wire and tape, and there have been performed critical currents on the MgB2 tape. The aim for the Master?s thesis was to find the relationship between the twist pitch and the losses of a multifilamentary wire. Calorimetric AC loss measurements have been performed on seven different lengths, from 3 mm to 50 mm, of the round multifilamentary MgB2 wire. These measurements have been performed by applying AC magnetic fields from 40 mT to 210 mT with a frequency between 15 Hz to 260 Hz at three different temperatures. At 50 Hz, 100 mT and 35 K the AC losses reduces by a factor of 6 by reducing the sample length of 12 mm, 29 mm or 50 mm to 3 mm. From theoretical calculations, it is believed that by reducing the twist pitch of a long sample from 24 mm to 6 mm the benefit from twisting will be at a maximum.

Place, publisher, year, edition, pages
Institutt for elkraftteknikk , 2013. , 63 p.
URN: urn:nbn:no:ntnu:diva-21887Local ID: ntnudaim:9583OAI: diva2:644986
Available from: 2013-09-02 Created: 2013-09-02 Last updated: 2013-09-02Bibliographically approved

Open Access in DiVA

fulltext(2326 kB)120 downloads
File information
File name FULLTEXT01.pdfFile size 2326 kBChecksum SHA-512
Type fulltextMimetype application/pdf
cover(184 kB)14 downloads
File information
File name COVER01.pdfFile size 184 kBChecksum SHA-512
Type coverMimetype application/pdf

By organisation
Department of Electrical Power Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 120 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available