IDENTIFIERING AV BÄSTA PLATS OCH MÄTMETOD FÖR TEMPERATURMÄTNING EFTER VÄRMEVÄXLARE
Örebro University, School of Science and Technology.
2013 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
IDENTIFICATION OF THE BEST METHOD AND LOCATION FOR TEMPERATURE MEASUREMENT AFTER HEAT EXCHANGER (English)
Abstract [sv]

Detta arbete har haft till syfte att utreda ett eventuellt temperaturmätfel efter en värmeväxlare i en kylkedja. I tidigare utförda rapporter om denna kylkedjas kapacitet finns en misstanke om att temperaturen ej mäts korrekt. En av anledningarna till en felaktig temperaturmätning kan vara att mätpunkten sitter för nära värmeväxlaren.

Första delen av arbetet har bestått av en litteraturstudie med syfte att ge kunskap om mätmetoder, och bakomliggande teori. Här har även information från tidigare rapporter om denna kylkedja inhämtats. Den andra och största delen av arbetet har varit att med termoelement mäta temperaturen på två olika platser i systemet. De insamlade mätvärdena har sedan analyserats, med målet att fastställa huruvida temperaturen mäts korrekt eller ej.

Mätningarna visar att det finns en viss stråkbildning efter värmeväxlaren, samt att det skiljer ca 0,5˚C mellan de uppmätta värdena och de som fås från den ordinarie givaren. Rekommendationen utifrån detta är att den ordinarie givaren bör flyttas längre nedströms i förhållande till värmeväxlaren.

Abstract [en]

The main goal with this report has been to investigate a suspected temperature measurement error after a heat exchanger. Previous reports concerning this heat exchanger leads to a suspicion that the temperature is measured incorrectly. One reason to why it might be incorrect could be the placement of the sensor, which is located quite close to the heat exchanger.

The first part of this task has been a literature study with the goal to increase my knowledge about different measurement techniques, and how to apply them in practice. This segment also contained gathering of information from previous reports. The second and largest part of the task has been to measure the temperature in two places after the heat exchanger using thermocouples. The data that has been collected was analyzed with the goal to determine whether the temperature is measured correctly or not.

The measurements indicated inhomogeneous temperatures directly after the heat exchanger, and a difference of 0,5˚C between the original sensor and the thermocouples. My recommendation from this study will be to move the temperature sensor further away from the heat exchanger.

Place, publisher, year, edition, pages
2013.
Keywords [sv]
Temperaturmätning, Termoelement, Värmeväxlare
National Category
Other Mechanical Engineering
Identifiers
URN: urn:nbn:se:oru:diva-30035OAI: oai:DiVA.org:oru-30035DiVA, id: diva2:637061
Subject / course
Mechanical Engineering
Supervisors
Examiners
Available from: 2013-07-16 Created: 2013-07-16 Last updated: 2017-10-17Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
School of Science and Technology
Other Mechanical Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 504 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf