Ventilationsbuller: Teknik och ekonomi för ett tyst system
Karlstad University, Faculty of Technology and Science, Department of Energy, Environmental and Building Technology.
2013 (Swedish)Independent thesis Basic level (university diploma), 15 credits / 22,5 HE creditsStudent thesisAlternative title
Noise occurrence due to the ventilation : Technology and economics for a quiet system (English)
Abstract [sv]

Buller från ventilationssystem är ofta förekommande och påverkar oss mer eller mindre varje dag. Det finns krav på hur mycket det får låta ur ventilationssystemet som är uppsatta av Karlstads Kommun med utgångspunkt från Boverkets Byggregler, men hur ser möjligheterna ut för att kunna konstruera ett tystare ventilationssystem vid en skärpt kravnivå?

Syftet är att utreda vilken kravnivå som är rimlig med hänsyn till teknik och ekonomi. Med utgångspunkt från Råtorps Förskola, som ägs och drivs av Karlstads Kommun, utförs beräkningar med hjälp av befintligt beräkningsmall samt ljudmätningar enligt Svensk Standard. Det görs för att ta reda på hur ljudmiljön i förskolan ser ut idag i relation till de krav som ställts. Vidare analyseras personalens uppfattning av ljudalstringen från ventilationen för att kunna konstatera vad som är en accepterad bullernivå. Därefter genomförs beräkningar av teoretiska förbättringsåtgärder för att ta reda på vad som krävs, framförallt tekniskt men även ekonomiskt, för att sänka ljudnivån.

Enligt de ljudmätningar som gjorts så ligger ljudnivån på förskolan under eller i nivå med den kravnivå som finns. De resultaten stämmer överens med de beräkningar som gjorts förutom att det rummet som tidigare låg i nivå med kravnivå nu istället ligger över gränsen. Ljudalstringen uppfattas som delvis störande i två av de fyra rummen, men resultaten av de teoretiska förbättringsåtgärder som beräknats visar på att det går att sänka ljudnivån markant, till en nivå som är inte direkt störande. Detta kan göras utan större ekonomiska konsekvenser, då den mest kostsamma och omständiga förbättringsåtgärden som testats visade sig vara minst effektiv för att sänka ljudnivån.

Arbetet resulterar i att även fast uppsatta krav följs så upplevs ventilationen till viss del som störande ändå. Det skulle gå att sänka ljudalstringen med relativt små medel utan allt för stora ekonomiska konsekvenser och på så sätt skapa en bättre arbetsmiljö. 

Abstract [en]

Noise from the ventilation systems affects us more or less every day. There are some requirements on how much noise that’s allowed to generate from the ventilation system set by Karlstads Kommun based on Boverkets Byggregler. But how could a more silent system be constructed at a more stringent level of requirements?

The aim is to investigate a reasonable sound level based on technology and economics. Based on Råtorps preschool, owned and operated by Karlstads Kommun, performed calculations using the existing calculation template and sound measurement according to a Swedish Standard. It is done to find out how the sound environment of preschool looks like today in relation to the requirements set. An analyze of the staff's perception of sound generation from ventilation to be able to consider what is an acceptable noise level. Subsequently, calculations are made to find out which theoretical improvements that can be done, especially technically and also financially, in order to reduce the noise level.

According to the noise measurements that are made, the noise level at the preschool is below or at the same level as the requirements. The results are consistent with the calculations performed in addition to the room that previously was in line with the requirements, now is over the limit. The noise from the ventilation is perceived as disruptive in two of the four rooms, but the results of the theoretical improvements are showing that it is possible to reduce the noise to a more acceptable level. This can be done without major financial consequences, than the most costly and improvement measure that was tested found to be least effective in lowering the noise level.

This work results in that even though the set requirements are followed as perceived ventilation to some extent as disturbing nonetheless. It would be possible to reduce noise generation with relatively small funds without excessive economic consequences and thus create a better working environment.

Place, publisher, year, edition, pages
2013. , 24 p.
Keyword [sv]
Ventilation, ventilationsbuller, buller
National Category
Engineering and Technology Energy Engineering
Identifiers
URN: urn:nbn:se:kau:diva-28140Local ID: EM:1OAI: oai:DiVA.org:kau-28140DiVA: diva2:631698
Educational program
Bachelor of Science in Enviromental and Energy Engineering, 180 hp
Supervisors
Examiners
Available from: 2013-06-26 Created: 2013-06-23 Last updated: 2013-06-26Bibliographically approved

Open Access in DiVA

fulltext(1367 kB)1598 downloads
File information
File name FULLTEXT01.pdfFile size 1367 kBChecksum SHA-512
56ac7013d0b0fdbbe4aaeb59ce2289f7c765e2b758e93f7808eebaaac4e7cc40178631c81144d6688c30104ed663eb9f08b10affebd07046504a0a9078d5820a
Type fulltextMimetype application/pdf

By organisation
Department of Energy, Environmental and Building Technology
Engineering and TechnologyEnergy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1598 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 518 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf