Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energieffektivisering genom ombyggnad: Med hjälp av VIP-Energy
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2013 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Energy efficiency through renovations : With VIP-Energy (English)
Abstract [sv]

Detta examensarbete har genomförts i samarbete med Värmex AB där vi har haft Anders Ericsson som handledare, och Peter Hansson (Sweco) som handledare från skolan, Kungliga tekniska högskolan i Haninge.

Idag är energianvändningen i flerbostadshus en stor fråga att ta itu med, och för varje byggnadsprojekt skall en energideklaration som visar mängd köpt energi göras. Vi strävar idag efter att minska energianvändningen i flerbostadshus med 50 % till 2050. I denna analys beskriver vi vilka åtgärder man kan ta an för att minska just energianvändningen i ett specifikt flerbostadshus belägen i kommunen Nacka i Stockholm.

Då denna byggnad stått från år 1949 utan större underhållning har det visat sig att byggnaden står över BBRs krav gällande energianvändning (90 kWh/m2), och stor anledning är klimatskalet. Källor visar även att delar av klimatskalet så som fasad etc. bör ändras inom 30 år efter det att det byggts, vilket inte har gjorts.

Vi har genom en programvara, VIP-Energy valt att utföra denna analys. Med hjälp av offentliga handlingar från stadsbyggnadskontoret så som plan – sektion – fasadritningar har vi mätt nödvändiga mått som vi knappat in i programmet. Även information som byggnadsmaterial, läge på byggnaden och uppvärmningssystem har varit nödvändiga. Jämförelse mot BBRs krav har gjorts automatiskt i programmet och det är sådan slags information vi utgått ifrån. 

Då vi i denna analys valt att fokusera på klimatskal där tak, golv, väggar, fönster och dörrar ingår visar resultatet att lägre u-värden på byggnadsdelar bidrar till lägre energianvändning. Studier visar att ca 35 % av värmeförlusterna är via fönster, och detta överensstämmer med byggnaden som denna analys är baserad på. Som lösning till detta har vi valt att byta fönster till 2-glas fönster med isolleruta vilket har betydligt lägre u-värde än de vi har idag. Vi vill även förbättra karmen och fogen kring fönstren för att minska transmissionsförlusterna och eventuella drag i bostäderna, vilket i sin tur leder till bättre komfort och skönare atmosfär. Detsamma gäller yterdörrarna som behöver bytas för att hålla värmen inne. Utvändig isolering i ytterväggen bidrar även med förbättringar kring u-värde och energianvändning.

Originalhuset visade att byggnadens genomsnittliga U-värde ligger på 0,656W/m2K och energianvändningen ligger på 96 kWh/m2 per år. Enligt BBRs krav för äldre byggnader ska u-värdet ligga på 0,400W/m2K och energianvändningen på 90kWh/m2 per år. Energibalansberäkningen visar nya värden på byggnaden, vilket är totala u-värde på 0,409 W/m2K samt energianvändningen på 64 kWh/m2.

Abstract [en]

This degree project has been written in collaboration with Värmex AB, with the generous help of Anders Ericsson as our fellow adviser and Peter Hansson (Sweco) our mentor from the Royal institute of technology located in Haninge.  

Today we find questions pertaining to energy consumption in apartment blocks of real significance; with each building project a declaration that shows the amount of energy consumed is of outmost importance. We strive to reduce energy consumption in apartment blocks by 50 % until year 2050. In this degree thesis, we aim to describe measures and solutions to lower the consumption of energy in a specific apartment block located in Nacka, Stockholm.  

This building has been standing quite untouched and unmarked since 1949, yet it is still in compliance with the demands stated by BBR concerning energy efficiency, in large because of its climate shell. Sources show that greater parts of its outer shell for example the front, should have been repaired during the first 30 years, and the matter is still to be solved.

The use of a computer software VIP-Energy has enabled us to state a hypothesis. With the help of public documents from Housing And Urban Development Town Building Office (HUD) giving us an overview of the different dimensions of the building, we've been able to plot all this data into the software. Information such as building materials, location, heating systems have also been necessary in our analysis. Results are automatically compared to the demands required by BBR. It is through experimentation of this data that we have been successful in collecting our results. 

In the analysis, we chose to focus on the climate shell that constitutes: roof, floors, walls, windows and doors. Our results show that lower U-values conduce better energy efficiency.

Studies show that almost 35 % of energy loss in a building is caused by the windows of the building, this this is consistent with the building which this analysis is based on.

We have solved this by changing sheet glass that is energy efficient. We also aim to change the frame and seams surrounding the windows, in order to lower transmission losses and possible draughts in the apartments. This will result in hopefully a higher degree of comfort and refreshing atmosphere. The same changes apply to entry doors in order to keep energy loss to a minimum. Also an external insulation in the outer wall contributes to improvements on u-value and use.

 The original building shows an average U-value of 0,656W/m2K and the energy consumption is 96 kWh/m2 per year. According to BBR, older buildings should have a U-value of 0,400W/m2K and an energy consumption of 90kWh/m2 per year. Energy balance calculation show new values for the building were the u -value should be set to 0,409W/m2K, and energy consumption should be set to 64kWh/m2.

Place, publisher, year, edition, pages
2013. , 51 p.
Keyword [en]
energy efficiency, heat loss, u-value, climate shell
Keyword [sv]
energieffektivisering, värmeförluster, u-värde, klimatskal
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-121972OAI: oai:DiVA.org:kth-121972DiVA: diva2:619792
External cooperation
Värmex AB; Sweco
Educational program
Bachelor of Science in Engineering - Constructional Engineering and Design
Uppsok
Technology
Supervisors
Examiners
Available from: 2013-05-06 Created: 2013-05-06 Last updated: 2013-05-06Bibliographically approved

Open Access in DiVA

fulltext(1688 kB)706 downloads
File information
File name FULLTEXT01.pdfFile size 1688 kBChecksum SHA-512
cb5559545804f3f1ed4099fe08dd6292da49e4a4ed0a53116a55bd0bbde7dec715a25bfbf241f7bae4d2ce6aac06ea6c3a2b59366f32aa90d476ceb6feea1c5b
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 706 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1304 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf