Efficient Streaming of Medical Sensor Data
KTH, School of Information and Communication Technology (ICT).
2012 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Telemedicine extends medical services to patients in remote areas. Due to the trend of population ageing, telemedicine becomes more and more popular. The Internet provides great opportunity for transmitting medical data. However the Internet is unreliable, some uncontrollable network behaviors (such as packet loss, packet delay) influence the quality of medical services greatly. Additionally,most existing medical data formats are designed for storing medical records not for streaming medical data over an unreliable medium.

In order to promote the efficiency and achieve the error control of medical sensor data streaming service, this project aims to 1) investigate different streaming protocols and encoding strategies;2) empirically evaluate these encoding strategies and find an optimum choice.In this project, we focus on a home-based electrocardiograph(ECG) sensor monitoring service which requires little overhead, low latency and constant data rate. We develop a framework for testing the efficiency of medical streaming service, and empirically evaluate four forward error correction (FEC) encoding strategies with different erasure codes (XORcod,RS code) and block interleavers. The performances of the four encoding strategies are measured by calculating the Repair Rate &Peak Signal Noise Ratio (PSNR), and the processing times of these encoders are measured as well. Network simulation is used to establish the unreliable network and Network Simulator3 (NS3) is employed as the simulation tool.

From the simulation results,we come up the conclusions: Firstly, the average burst error length of a network is the key factor which influences the performance comparison of the four encoding strategies.Secondly, interleaving provides positive impact when packet losses are bursty; while it results in negative impact when packet losses are scattered.Based on the conclusions above, FEC-XOR-Interleaving encoding strategy is the optimum choice for the home-based ECG sensor monitoring scenario,

Place, publisher, year, edition, pages
2012. , 66 p.
TRITA-ICT-EX, 2012:313
Keyword [en]
telemedicine, medical sensor, encoding strategy, streaming protocol
National Category
Engineering and Technology
URN: urn:nbn:se:kth:diva-121519OAI: diva2:618642
Educational program
Master of Science -Communication Systems
Available from: 2013-04-29 Created: 2013-04-29 Last updated: 2014-10-15Bibliographically approved

Open Access in DiVA

fulltext(2259 kB)319 downloads
File information
File name FULLTEXT01.pdfFile size 2259 kBChecksum SHA-512
Type fulltextMimetype application/pdf

By organisation
School of Information and Communication Technology (ICT)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 319 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 104 hits
ReferencesLink to record
Permanent link

Direct link