Change search
ReferencesLink to record
Permanent link

Direct link
Membrane Based Heat Exchanger
Norwegian University of Science and Technology, Faculty of Engineering Science and Technology, Department of Energy and Process Engineering.
2012 (English)MasteroppgaveStudent thesis
Abstract [en]

Reduction of the energy used to acclimatise buildings is a huge challenge simultaneously with the implementation of air tight low energy buildings. In residential buildings with several living units centralised air handling units are the most energy efficient system. However, in a centralised system there is important to avoid leakages of pollutions between the exhaust air and the supply air. This leads to that flat plate heat exchangers are used instead of the more energy efficient rotary heat exchanger in these types of buildings. Flat plate heat exchangers will have problems concerning water condensation and frost formation in the exhaust air channels at low supply inlet temperatures. In this thesis a membrane based heat exchanger, which also was able to transfer moisture, was compared to a plastic based heat exchanger to see if the membrane based exchanger had less problems concerning condensation and freezing. In addition a mathematical method was derived to predict the heat and moisture transfer effectiveness in a membrane based heat exchanger. To compare the different heat exchanger plate materials a test rig was built in the laboratory at the Department of Energy and Process Engineering at NTNU. The experiments showed that the plastic based heat exchangers had problems with condensation and freezing in the tested conditions. The membrane based exchanger did not experience the same problems. However, additional problems with expansion of the membrane in high humidity showed that the tested membrane had drawbacks and was not really suitable. The derived mathematical method to predict the moisture transfer effectiveness was shown to correlate very well with the experimental results. The derived method and the developed Microsoft Excel tool called HXcalc may then be used to investigate other membranes moisture transfer effectiveness.

Place, publisher, year, edition, pages
Institutt for energi- og prosessteknikk , 2012. , 140 p.
Keyword [no]
ntnudaim:7916, MTPROD produktutvikling og produksjon, Energi-, prosess- og strømningsteknikk
URN: urn:nbn:no:ntnu:diva-18660Local ID: ntnudaim:7916OAI: diva2:566164
Available from: 2012-11-08 Created: 2012-11-08

Open Access in DiVA

fulltext(9243 kB)912 downloads
File information
File name FULLTEXT01.pdfFile size 9243 kBChecksum SHA-512
Type fulltextMimetype application/pdf
cover(266 kB)57 downloads
File information
File name COVER01.pdfFile size 266 kBChecksum SHA-512
Type coverMimetype application/pdf
attachment(790 kB)82 downloads
File information
File name ATTACHMENT01.zipFile size 790 kBChecksum SHA-512
Type attachmentMimetype application/zip

By organisation
Department of Energy and Process Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 912 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 482 hits
ReferencesLink to record
Permanent link