Ultrasound Transducers. Function and Quality Control in Hospitals
KTH, School of Technology and Health (STH), Medical Engineering.
2012 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Nowadays, most of the medical technology manufacturers try to meet the high demands of quality and design of ultrasound equipment, including transducers: easy to use, flexible image handling, multi frequencies operation use of various applications, good resolution and penetration. It is known that this kind of medical devices is extremely sensitive and should be maintained in compliance with the necessary physical and functional requirements, via regular tests (Moore, 2006).

This master thesis has two purposes. The major one is to examine the physical and functional status of every single transducer in Gävleborg hospitals. It allows defining a possible problem before it has influenced formation image and diagnosis. The second purpose is to find out the advantages and disadvantages of using the ultrasound evaluation test FirstCall aPerio Testing Accreditation Program, manufactured by Sonora Medical System in Longmont, USA (www.4sonora.com).The scientific method of this evaluation test is based on three steps which are as follows: testing of ultrasound transducers, classified data collection and analysis.

The evaluation test used in this report is a highly qualified system which has been designed to avoid and minimize diagnostic risks, and at the same time, maximize patient’s safety. It allows distinguishing any hidden manufacturing defects with new devices or those appearing during the operation period.

For this evaluation test, 73 transducers were controlled, belonging to clinics of four different hospitals within the Gävleborg area. Tested transducers were manufactured by Siemens, GE Healthcare and Aloka. A total of 61 of transducers passed the test and 12 did not pass it. 

Finally it was observed, that the reason for not passing the evaluation test was mostly due to dead elements in a row in the centre of the transducers.

Thanks to the software program of FirstCall aPerio, the results of the evaluation test are immediately visible, through the report. It is useful in early discovering the source of error in transducer and minimizing of wrong diagnosis. The testing system gives a possibility to test the transducer without US equipment and to collect the database information.

Keywords: ultrasound, FirstCall aPerio Testing Accreditation Program, ultrasound transducers, evaluation test, wrong diagnosis.

Place, publisher, year, edition, pages
2012. , p. 40
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-103407OAI: oai:DiVA.org:kth-103407DiVA, id: diva2:559963
External cooperation
Landstinget Gävleborg
Subject / course
Medical Engineering
Educational program
Master of Science - Medical Engineering
Presentation
2012-04-24, STH Plan 3, ANA10, SE-141 86, Flemingsberg, Sweden, 09:38 (English)
Uppsok
Technology
Supervisors
Examiners
Available from: 2019-09-11 Created: 2012-10-11 Last updated: 2022-06-24Bibliographically approved

Open Access in DiVA

fulltext(1334 kB)2847 downloads
File information
File name FULLTEXT01.pdfFile size 1334 kBChecksum SHA-512
d471fb3ae9b0692754a2e5514e35725f2a3e7280de095b0bf477012a31620cd9850c67731ed353f152255c561c3e36afc7a2e48efbbea366fd58efc74b437625
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Hassoun, Abdallah
By organisation
Medical Engineering
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 2850 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 482 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf