Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Biochemistry and Microbiology.
2012 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Introduction: It is recommended to place all the vacuum tubes directly on a sample cradle after vein puncture to prevent analytic error. This recommendation is not always easy to follow because the samples are taken by different professionals under different situations.  The three most common analyses, platelets count, haemoglobin and prothrombin time were tested.  Therefore, it was interesting to compare results from the three most common analyses with or without sample cradle, to evaluate the influence of this step on the result. Methods: Three analyses were preformed, using blood from 50 different persons. Each person gave two vacuum tubes, each contained 4.5mL of venous blood for the study. Tubes containing EDTA were used for platelet counts and measurement of haemoglobin and tubes containing citrate were used for prothrombin time-analysis. One of the tubes was placed, as recommended, directly on the sample cradle while the other tube was placed flat on a bench for 10 minutes before it was placed on the sample cradle. Results: There was a clear difference in platelet counts with and without immediate cradling but only minor difference between the results for haemoglobin and International Normalized Ratio. Conclusion: Some analyses seem to be more sensitive for variation in cradling than others. For platelet count it was important to immediately rock the tubes but for determination of prothrombine time and hemoglobin it had a small impact. The small impact on the results is probably due to the efficiency of the anticoagulant in the vacuum tubes.

Place, publisher, year, edition, pages
2012. , 17 p.
Keyword [en]
vein puncture, coagulation, International Normalized Ratio, citrate, EDTA
National Category
Medical and Health Sciences Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:uu:diva-182146OAI: oai:DiVA.org:uu-182146DiVA: diva2:558578
Educational program
Biomedicinska analytikerprogrammet
Uppsok
Medicine
Supervisors
Examiners
Available from: 2012-10-04 Created: 2012-10-04 Last updated: 2012-10-04Bibliographically approved

Open Access in DiVA

fulltext(242 kB)471 downloads
File information
File name FULLTEXT01.pdfFile size 242 kBChecksum SHA-512
b66ae87b0268c6e69e5cdb006a63e1d1274dbe269667cea4df92303c8bdffdf9042d01e35bae604baa84cea122d3e84a3993462e9faa6dcf74321d06a7430348
Type fulltextMimetype application/pdf

By organisation
Department of Medical Biochemistry and Microbiology
Medical and Health SciencesBiomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 471 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 611 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf