Fuktåterföring i roterande värmeväxlare
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2012 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Moisture feedback in rotating heat exchanger (English)
Abstract [sv]

För att ha en chans att ändra trenden med ökande utsläpp av växthusgaser är internationella samarbeten nödvändiga. Därför har EU genom miljökvalitetsmålet Begränsad Miljöpåverkan satt krav på högsta tillåtna utsläpp av växthusgaser. Att sänka energianvändningen för upp- värmning är ett steg i att även sänka utsläpp av koldioxid, som är en av växthusgaserna. Sänkning av energianvändning kan göras på flera sätt, bl.a. genom att öka tjockleken på isoleringen eller återvinna värmen i frånluften. Men dessa åtgärder ska inte helt okritiskt göras.  Att använda roterande värmeväxlare är ett sätt att återvinna värmen i frånluften. Luften passerar då en rotor med öppna kanaler som roterar kring sin egen axel över till tilluftssidan. Detta möjliggör fuktöverföring oberoende om rotorn är hygroskopisk eller ej. Dvs. möjligheten för kanalväggen att ta upp vattenmolekyler eller inte.  Mätningar av relativ fuktighet, temperatur och daggpunkt har gjorts på tre objekt. Därefter har ånghalter och verkningsgrader beräknats. Med objekt menas småhus där roterande värmeväxlare installerats i ventilationssystemet. Objekten är belägna i Linköping, Stockholm och Norge. Ett beräkningsexempel har ställts upp som visar hur fuktverkningsgraden påverkas av olika fukttillskott. I verkligheten råder dock inte stationära förhållanden för fukttillskottet som är en förutsättning för resultaten på dessa beräkningsexempel.  I denna rapport kommer den skrivande således fram till att fuktåterföring sker även för icke hygroskopiska värmeväxlare. Även att fuktverkningsgraden svarar med en viss tröghet vid återhämtning av ett tillfälligt förhöjt fukttillskott. Fuktverkningsgraden är dock betydande för fukttillskott över ca 1-2 g/m3. 

Abstract [en]

To have a chance to change the trend of increased greenhouse gases are international collaborations necessary. Therefore, the EU through the environmental quality objective of Reduced Environmental Impact sat requirements for maximum allowable emissions of greenhouse gases. Reducing energy use for heating is a step that also reduces emissions of carbon dioxide; which is one of the greenhouse gases. Reducing energy use can be done in several ways, including by increasing the thickness of the insulation or heat recovery from exhaust air. However, these measures should not be uncritically made. The use of a rotating heat exchanger is a means to recover heat from exhaust air. The air then passes a rotor with open channels that rotates around its own axis over to the supply air side. This allows moisture transfer regardless of whether or not the rotor is hygroscopic. That is, the ability of the channel wall to take up water molecules or not.  Measurements of relative humidity, temperature and dew point has been made on three objects. Thereafter steam content and efficiencies was calculated. In other words, the objects are referred to single- ore two-family homes where a rotary heat exchanger is installed in the ventilation system. The objects are located in Linköping, Stockholm and Norway. An example calculation is set up that shows how moisture efficiency is affected by different moisture addition. In reality in which the conditions is not stationary the moisture supplement that is a prerequisite for the results of these calculation examples.  In this report, the writer thus concluded that moisture reversal will occur even for non- hygroscopic heat exchangers. Although the moisture efficiency corresponds with a certain slowness in the recovery of a temporarily elevated moisture addition. Moisture efficiency is significant for moisture supplement of about 1-2 g/m3. 

Place, publisher, year, edition, pages
2012. , 46 p.
Keyword [en]
Rotating heat exchanger, moisture feedback, steam content, moisture addition, relative humidity (RH), moisture efficiency, temperature efficiency
Keyword [sv]
Roterande värmeväxlare, fuktåterföring, ånghalt, fukttillskott, relativ fuktighet (RF), fuktverkningsgrad, temperaturverkningsgrad
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:kth:diva-102116OAI: oai:DiVA.org:kth-102116DiVA: diva2:550959
External cooperation
AK-Konsult indoor air AB
Subject / course
Constructional Engineering and Design
Educational program
Bachelor of Science in Engineering - Constructional Engineering and Design
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-09-10 Created: 2012-09-09 Last updated: 2013-03-06Bibliographically approved

Open Access in DiVA

fulltext(5028 kB)1400 downloads
File information
File name FULLTEXT01.pdfFile size 5028 kBChecksum SHA-512
cab8a66df60425924a4376c93ce9d60c2e7368ae5f389d057ac87fdf86a7c6dfd08af4485bafcd263632e45c33c87b12c26e23ba25383b55a921ea402ab483e4
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1400 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 215 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf