Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energieffektiva byggnader ikallt klimat: En undersökning av energiprestanda förfyra enfamiljshus i Umeåregionen
Umeå University, Faculty of Science and Technology, Department of Applied Physics and Electronics.
2012 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Energy efficient buildings i cold climates (English)
Abstract [sv]

Under hösten 2011 har detta examensarbete utförts på uppdrag av institutionen för Tillämpad Fysik och Elektronik (TFE) på Umeå universitet. Examensarbetet är en del i det pågående projektet Energieffektivt byggande i kallt klimat, vilket är ett sammarbete mellan Umeå kommun, Umeå universitet och marknadsaktörer i Umeåregionen. Målet med arbetet är att ta fram och sammanställa ett gediget mätunderlag för att synliggöra möjligheterna till energibesparingar inom bostadssektorn samt undersöka om energieffektivare hus medför ökad risk för exempelvis mögel, röta och svamppåväxt. På sikt är förhoppningarna att detta skall leda till en ökad motivation att bygga energieffektivt även på dessa breddgrader.

En sammanställning av energibehovet har gjorts för 4 enfamiljsvillor i Umeåregionen under helåret 2011. Temperaturer och fukt har kontinuerligt loggats i olika skikt av husens byggnadsdelar, samt i inom- och utomhusluften. Flöden och temperaturer på vatten till värmesystem och tappvarmvatten har loggats. Elanvändningen har även den kontinuerligt samlats in. Sammanlagt har mellan 27 och 40 mätgivare varit installerade i respektive hus.

Energianvändningen har på detta sätt kunnat kartläggas och kategoriseras efter användningsområdena värme, tappvarmvatten, hushållsel samt total el- och energianvändning. Prestanda har undersökts för energibesparande installationer så som värmeväxlare, ett 30 m långt markförlagt förvärmningsrör för tilluft samt en bergvärmepump.

Resultaten från sammanställningarna visar att husen, med normalårskorrigerade värden, har ett energibehov till värme och tappvarmvatten på mellan 67 och 81 kWh/m2y. Värme- och varmvattenbehovet var i ett av husen endast hälften av det i BBR ställda kravet på 130 kWh/m2y för hus med annan typ av uppvärmning än direktverkande el.

Mätningarna visar att det inte föreligger någon risk för mögel eller röta någonstans i något av husen.

I ett av husen kunde ett markförlagt förvärmningsrör tillsammans med en väl fungerande värmeväxlare värma luften så effektivt att ingen ytterligare förvärmning av tilluften var nödvändig. Detta även under årets kallaste perioder.

Bergvärmepumpen som undersökts har i genomsnitt levererat 2,5 ggr mer energi än den förbrukat vilket reducerat mängden köpt energi till värme och tappvarmvatten med ca 60 % på årsbasis.

Sammantaget är det inte någonting i denna undersökning som tyder på några föreliggande problem med att bygga energieffektiva byggnader i kallt klimat. Ingen förhöjd risk för röta eller mögel har påvisats vilket annars är en vanlig missuppfattning kring energieffektiva, täta hus.

Istället tyder det mesta på att besparingsmöjligheterna är stora såväl för den egna plånboken som för miljön, både på kort som lång sikt.

Abstract [en]

This master thesis has been carried out in the autumn of 2011, on assignment of the department of Applied Physics and Electronics (TFE) at Umeå University. The thesis is a part of the ongoing project, Energieffektivt byggande i kallt klimat, which is a collaboration between the municipality of Umeå, Umeå university and market participants in the Umeå region. The goal of this work is to create and compile a solid base of measurements to show the energy saving potential in the housing sector and to explore if there is an increased risk of mold, rot or fungus growth in energy efficient houses. The long-term goal is that the result of this project will lead to increased motivation to build energy efficient houses even in these latitudes.

A compilation of the energy requirement has been made for four single-familyhouses in the Umeå region throughout the year 2011. Temperatures and humidity has continuously been logged in the various layers of the building components and in indoor and outdoor air. Flow rates and temperatures of water in heating systems and to hot tap water have been logged. Electricity consumption has also been continuously collected. In total, between 27 and 40 sensors were installed in each house.

The energy use has thereby been identified and categorized according to if the use is for heat, hot tap water, household electricity and in terms of total electricity- and energy use. Performance has been investigated for installations with energy saving purposes such as heat exchangers, a 30 m long preheating pipe buried in the ground and a geothermal heat pump.

The results of the compilations show that the houses, with normal year corrected values, have an energy requirement for heating and hot tap water at between 67 and 81 kWh/m2y. The heat and hot tap water requirement for one of the houses was only half of the requirement in BBR of 130 kWh/m2y for houses with other type of heating source than electrical heating.

The measurements show that there is no risk of mold or rot anywhere in any of the houses.

In one of the houses it was showed that a preheating pipe along with a wellfunctioning heat exchanger was enough so no additional pre-heating of the incoming air was necessary, even during the coldest period of the year.

The geothermal heat pump delivered in average 2.5 times more energy than it consumed. This reduced the amount of purchased energy for heating and hot tap water by about 60 % on a yearly basis.

Overall, there is nothing in this research that indicates that there are any hinders for constructing energy efficient buildings in cold climates. No increased risk of rot or mold has been detected which has been a common misconception about energyefficient, airtight houses.

Rather, there is a quite large saving potential both moneywise for the individual and for the environment, in both the short and the long term.

Place, publisher, year, edition, pages
2012. , 102 p.
Series
EN1204
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:umu:diva-58984OAI: oai:DiVA.org:umu-58984DiVA: diva2:550499
External cooperation
Umeå kommun och Bostaden
Educational program
Master of Science Programme in Energy Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-09-07 Created: 2012-09-07 Last updated: 2012-09-10Bibliographically approved

Open Access in DiVA

fulltext(13331 kB)251 downloads
File information
File name FULLTEXT01.pdfFile size 13331 kBChecksum SHA-512
d382e55bdd19a6a6dd152d9a304b9c413bd096b3970746c5ff7039010cf3b374ffb71bb43e28d4b3ad4112de5a973ddbdabb0e6bb708971d7540dc439c9f7da1
Type fulltextMimetype application/pdf

By organisation
Department of Applied Physics and Electronics
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 251 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 260 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf