Measuring Lymphedema Symptoms: Continuing the Development of a Medical Device
KTH, School of Industrial Engineering and Management (ITM), Machine Design (Dept.).
2012 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Denna rapport beskriver utvecklandet av ett medicinsktekniskt prototypverktyg för mätning av omkrets- och hårdhets-förändringar i armar och ben, för diagnostisering av lymfödem.

Lymfödem är en bieffekt vid cancerbehandling som blir vanligare i och med att cancerbehandling blir allt mer effektiv. Lymfödem visar sig vanligtvis som svullnad av armar eller ben som kan bli bestående om den inte behandlas. Genom att följa omkretsen i armar och ben hos patienter som har strålbehandlats eller opererats för cancer kan en terapeut upptäcka tendenser till svullnad tidigt för att inleda behandling i god tid.

Detta projekt baseras på ett tidigare projekt där ett verktyg för omkretsmätning tagits fram. Det är ett handhållet verktyg som matar en ring av måttband in och ut och sparar dess mått digitalt. Verktyget är tänkt att ersätta den nuvarande, manuella mätmetoden där måtten skrivs ner för hand och senare matas in i en dator. Fördelen med verktyget är att det ger en snabbare och mer pålitligt mätning. Resultatet från den manuella metoden kan variera mellan terapeuter medan verktyget är konsekvent i sina mått.

En annan viktig del av diagnosen är palpering/känsel efter stelhet i patientens hud. Denna rapport beskriver också utvecklandet av en metod för att kvantifiera hudhårdhet i mänsklig vävnad på ett objektivt sätt – något som idag inte existerar. Genom att integrera styvhetsmåttet i mätverktyget kan diagnosprocessen göras mer tillförlitlig och effektiv.

För att vara säker på att inte smittor sprids mellan patienter måste verktyget ha en ren gränsyta emot patienterna. För att möta detta krav har en engångsdel utvecklas som innehåller alla delar som kommer i kontakt med patienten och kan kastas efter bruk.

Resultatet av projektet är ett mätverktyg som kan mäta omkrets med ett konfidensintervall på ± 3 mm. Samtidigt som omkretsmätningen utförs mäts också hudstyvheten genom att mäta hudens kompressabilitet. De viktiga egenskaper som uppnåtts hos styvhetsvärdet är förmågan att detektera skillnad i styvhet i olika material av samma omkrets samtidigt som värdet är oförändrat när samma material varierar i omkrets.

Mätverktyget sparar minst 30 – 50 % av den tid som går åt till mätning. Verktyget minimerar också påverkan av den mänskliga faktorn under mätprocessen.

1

Abstract [en]

This report describes project of developing of a medical device prototype for measuring changes in circumference and hardness in limbs, for diagnosing patients for lymphedema.

Lymphedema is a side-effect of cancer treatment and it is becoming more common as cancer treatment is becoming more effective. Lymphedema presents itself as a swelling of the limbs, usually arms and legs, the swelling may become irreversible if left untreated. By tracking the circumference of the limbs of patients who have had cancer surgery or radiation treatment, therapists want to detect tendencies for swelling as soon as possible to be able to administer treatment as soon as possible.

This project is based on a previous project; the development of a device for tracking the circumference of the limbs of patients. The device is a handheld tool which feeds a loop of tape measure in and out, storing its measurements digitally. It is intended to replace the current, manual measuring technique where measurements are written down by hand and later fed into a PC. The benefit of a device is that it is faster and more reliable. The manual measuring technique may differ from one therapist to the next, while the device is consistent in its measurements.

Another important part of the diagnosis is palpating/feeling an approaching stiffening of the patient’s skin. This report also describes the development of a method for objectively quantifying the stiffness of human tissue – something that currently does not exist. By incorporating this into the device the process of diagnosing patients becomes more reliable.

To make sure that contaminants are not transferred between patients the device needs to have a clean interface toward patients. To cater to this, a disposable part, containing all parts that come into contact with the patient, is developed too.

The result is a device that can measure circumference with a confidence interval of ± 3 mm. As it measures the circumference it simultaneously assesses the stiffness of the skin by measuring its compressibility. The important properties achieved for the stiffness value are that the value will change for different materials of the same circumference while it remains the same for a specific material as it differs in circumference.

The device will save at least 30 – 50 % of time spend measuring. It also reduces the influence of human error in the measuring process greatly.

3

Place, publisher, year, edition, pages
2012.
Series
MMK 2012:16 MKN 428
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-99286OAI: oai:DiVA.org:kth-99286DiVA: diva2:541782
External cooperation
Sister Kenny Research Center,Lars Oddsson
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-07-23 Created: 2012-07-23 Last updated: 2012-07-24Bibliographically approved

Open Access in DiVA

Thomas Sederholm(2555 kB)370 downloads
File information
File name FULLTEXT01.pdfFile size 2555 kBChecksum SHA-512
458b086920a4b79cbdba00a70bfd9bcb719c50e35ae85375c20a7513e7b8caece317ee5c701f48aa3b3be0a15f895cc6f59b78d27e150a0b1321d161f0f29e2a
Type fulltextMimetype application/pdf

By organisation
Machine Design (Dept.)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 370 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 168 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf