Assessment of optical coherence tomography for metrology applications in high-scattering ceramic materials
KTH, School of Industrial Engineering and Management (ITM), Production Engineering, Metrology and Optics. (Metrology and Optics)ORCID iD: 0000-0003-0776-3716
2012 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Large-scale and cost-effective manufacturing of ceramic micro devices based on tape stacking requires the development of inspection systems to perform high-resolution in-process quality control of embedded manufactured cavities, metal structures and defects.

In this work, alumina ceramic samples are evaluated by optical coherence tomography (OCT) operating at 1.3μm wavelength and some dimensional data are obtained by dedicated image processing and segmentation. Layer thicknesses can be measured and laser-machined channels can be verified embedded at around 100μm depth. Moreover, detection of internal defects is enabled.

Monte Carlo ray tracing simulations are employed to analyze the abilities of OCT in imaging of the embedded channels. The light scattering mechanism is studied for the alumina ceramics, and different scattering origins and models are discussed. The scattering parameters required as input data for simulations are evaluated from the integrating sphere measurements of collimated and diffuse transmittance spectra using a reconstruction algorithm based on refined diffusion approximation approach.

 

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2012. , vii, 61 p.
Series
Trita-IIP, ISSN 1650-1888 ; 2012:07
Keyword [en]
metrology, optical coherence tomography, alumina ceramics, nondestructive testing, imaging through turbid media, light scattering, image processing, numerical approximation and analysis, Monte Carlo method
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-98621ISBN: 978-91-7501-398-5 (print)OAI: oai:DiVA.org:kth-98621DiVA: diva2:538013
Presentation
2012-06-08, Sal M311, KTH, Brinellvägen 68, Stockholm, 14:00 (English)
Opponent
Supervisors
Funder
XPRES - Initiative for excellence in production research
Note

QC 20120628

Available from: 2012-06-28 Created: 2012-06-28 Last updated: 2014-04-28Bibliographically approved
List of papers
1. Depth profiling in alumina ceramic by optical coherence tomography
Open this publication in new window or tab >>Depth profiling in alumina ceramic by optical coherence tomography
2010 (English)In: Proceedings of the 7th International Conference on Multi-Material Micro Manufacture / [ed] Bertrand Fillon, Chantal Khan-Malek, Stefan Dimov, Singapore: Research Publishing Services, 2010, , 323 p.316-319 p.Conference paper, Published paper (Refereed)
Abstract [en]

Quality inspection of multi layer ceramic micro devices is a challenging task for large-scale production. Detection of embedded cavities, metal strips or defects within a sintered multi layer alumina ceramic stack is one of the research areas under investigation in the EU-Multilayer project. Since visible light is highly scattered in the turbid alumina, traditional optical imaging techniques fails and acoustic microscopy requires the structure to be soaked in a liquid for good acoustic coupling. In this paper we investigate the performance of optical coherence tomography (OCT) as a candidate for inspection of alumina films. To understand how deep we can “see” through the alumina material, an optical scattering model is built up based on the study of microstructure of the sintered alumina sample. The investigated sample has high purity, more than 1% porosity and an average pore size of 0.8 µm. By applying optical coherence tomography (OCT) to a sintered tapered alumina ceramic sample for the first time, a depth profile of sample is obtained with high resolution. The maximum detectable thickness was is 0.26 mm using an OCT system with center wavelength at 1.3 µm and axial resolution of 12 µm.

Place, publisher, year, edition, pages
Singapore: Research Publishing Services, 2010. 323 p.
Keyword
Alumina, turbid media, optical coherence tomography (OCT), light scattering, inspection, metrology
National Category
Engineering and Technology
Research subject
SRA - Production
Identifiers
urn:nbn:se:kth:diva-48443 (URN)10.3850/978-981-08-6555-9_187 (DOI)978-981-08-6555-9 (ISBN)
Conference
4M 2010 Conference
Projects
FP-7 Multilayer project
Funder
EU, FP7, Seventh Framework Programme, FP7-NMP4-2007-214122XPRES - Initiative for excellence in production research
Note

Qc 20111216

Available from: 2012-01-11 Created: 2011-11-18 Last updated: 2014-04-28Bibliographically approved
2. Optical coherence tomography: a potential tool for roughness assessment of free and embedded surfaces of laser-machined alumina ceramic
Open this publication in new window or tab >>Optical coherence tomography: a potential tool for roughness assessment of free and embedded surfaces of laser-machined alumina ceramic
Show others...
2011 (English)In: Proceedings of the 8th International Conference on Multi-Material Micro Manufacture / [ed] Heinz Kuck, Holger Reinecke and Stefan Dimov, Singapore: Research Publishing , 2011, 140-144 p.Conference paper, Published paper (Refereed)
Abstract [en]

For an emerging market a mass and cost-effective production of non-silicon micro devices requires an in-process and accurate 3D monitoring to assure the quality. Optical coherence tomography (OCT) providing high-resolution contactless imaging is used to inspect the surface quality of a laser-machined alumina ceramic layer. Quantitatively the root mean square (rms) roughness is measured by traditional means and provides input parameters to theMonte Carlosimulation of OCT method. We found that the quality of both free and embedded surfaces of the highly-scattering alumina ceramic material can be evaluated by OCT.

Place, publisher, year, edition, pages
Singapore: Research Publishing, 2011
Keyword
Alumina ceramics, optical coherence tomography (OCT), light scattering, surface roughness, Monte Carlo method, laser machining
National Category
Engineering and Technology
Research subject
SRA - Production
Identifiers
urn:nbn:se:kth:diva-48468 (URN)10.3850/978-981-07-0319-6_247 (DOI)000307677000030 ()978-981-07-0319-6 (ISBN)
Conference
4M 2011 conference
Projects
Multilayer project (FP7-NMP4-2007-214122)
Funder
EU, FP7, Seventh Framework Programme, FP7-NMP4-2007-214122XPRES - Initiative for excellence in production research
Note

QC 20111221

Available from: 2011-12-21 Created: 2011-11-18 Last updated: 2014-04-28Bibliographically approved
3. Optical coherence tomography for quality assessment of embedded microchannels in alumina ceramic
Open this publication in new window or tab >>Optical coherence tomography for quality assessment of embedded microchannels in alumina ceramic
Show others...
2012 (English)In: Optics Express, ISSN 1094-4087, E-ISSN 1094-4087, Vol. 20, no 4, 4603-4618 p.Article in journal (Refereed) Published
Abstract [en]

Large-scale and cost-effective manufacturing of ceramic micro devices based on tape stacking requires the development of inspection systems to perform high-resolution in-process quality control of embedded manufactured cavities, metal structures and defects. With an optical coherence tomography (OCT) system operating at 1.3 mu m and a dedicated automated line segmentation algorithm, layer thicknesses can be measured and laser-machined channels can be verified in alumina ceramics embedded at around 100 mu m depth. Monte Carlo simulations are employed to analyze the abilities of OCT in imaging of the embedded channels. The light scattering parameters required as input data for simulations are evaluated from the integrating sphere measurements of collimated and diffuse transmittance spectra using a reconstruction algorithm based on refined diffusion approximation approach.

Place, publisher, year, edition, pages
Optical Society of America, 2012
Keyword
Optical coherence tomography, Nondestructive testing, Imaging through turbid media, Scattering, Image processing, Numerical approximation and analysis
National Category
Engineering and Technology
Research subject
SRA - Production
Identifiers
urn:nbn:se:kth:diva-85514 (URN)10.1364/OE.20.004603 (DOI)000301041900124 ()2-s2.0-84857331392 (Scopus ID)
Projects
Multilayer project (FP7-NMP4-2007-214122)
Funder
EU, FP7, Seventh Framework Programme, FP7-NMP4-2007-214122XPRES - Initiative for excellence in production research
Note

QC 20120221

Available from: 2012-02-21 Created: 2012-02-13 Last updated: 2017-12-07Bibliographically approved

Open Access in DiVA

fulltext(1618 kB)499 downloads
File information
File name FULLTEXT01.pdfFile size 1618 kBChecksum SHA-512
24f7b924f3c38ed5ecdcdc4d2d3cfbe0412f75e4d626581d09849621845d28ee5aab2f605579edef17c30ad2061b3775ae34fef46d81cc9a5aba37ced280faa7
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Su, Rong
By organisation
Metrology and Optics
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 499 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 599 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf