Fuktsäkerhet för takkonstruktion med variabel ångspärr: Tillämpning i modulhus
Karlstad University, Faculty of Technology and Science, Department of Energy, Environmental and Building Technology.
2012 (Swedish)Independent thesis Basic level (professional degree), 15 credits / 22,5 HE creditsStudent thesisAlternative title
Moisture control using a variable vapor barrier in roof construction : Application of modular houses (English)
Abstract [sv]

Byggbranschen har länge brottats med fuktproblem som följts av fuktskador. Nya tekniska lösningar, som skall få bukt med problemen, har inte alltid visat sig fungera. Med detta som bakgrund har en av dessa tekniska lösningar, en variabel ångspärr utretts.  

Moelven Byggmodul AB tillverkar modulhus av olika slag och i detta arbete har en ny takkonstruktion hos ett av deras modulsystem undersökts utifrån ett fuktsäkerhetsperspektiv. Det ursprungliga taket använder en ventilerad luftspalt för att ventilera bort fukt som kan förekomma. Enligt tillverkaren av den variabla ångspärren behövs inte längre den ventilerade luftspalten. Genom att byta ut den ventilerade luftspalten mot ett ytterligare lager med isolering kan värmebehovet för byggnaden minska vilket bidrar till lägre driftkostnader och i sin tur minskad miljöbelastning.

En variabel ångspärr har varierande ångenomsläpplighet beroende av luftens relativa fuktighet. På vintern är den relativa fuktigheten inomhus låg och då är ångspärren ångtät. Under sommaren är luftens relativa fuktighet hög och ångspärrens ånggenomsläpplighet större. En takkonstruktion med variabel ångspärr bygger på principen om uppfuktning och uttorkning hos ingående material. En fukttransport från takets uppfuktade delar till inomhusluften är möjlig då takets yttre delar värms upp av t.ex. solen.

En dynamisk beräkningsmodell har konstruerats för att ta hänsyn till temperatur- och fuktförhållanden hos takets ingående material. Genom att analysera resultatet har takets fuktsäkerhet kartlagts vid placering av modulen på olika platser i Sverige. Klimatdata såsom solstrålning, relativ luftfuktighet samt temperatur har tagits med i beräkningarna. 

Konstruktionens svagaste länk är spånskivan som är placerad närmast takets täckskikt. Den får problem med fukt först och blir dimensionerande. Beräkningsmodellens resultat visar att den undersökta takkonstruktionen med variabel ångspärr fungerar vid låg fuktbelastning i den södra delen av Sverige. I norra Sverige uppstår problem till följd av ett kallare klimat med lägre strålningseffekt från solen. Vid hög fuktbelastning löper den utredda takkonstruktionen en stor risk att drabbas av fuktskador, oavsett placering i landet.

Abstract [en]

The building construction industry has been struggling with moisture problems, followed by moisture damage, for a long time. New technical solutions, which purposes have been to overcome the problems, have not always been proven to work. With this in mind, one of these technical solutions, the variable diffusion barrier has been investigated.

 

Moelven Byggmodul produces modular houses of various types and sizes. In this study, a new type of roof construction has been investigated with focus on the ability to prevent moisture problems. The original ceiling uses a ventilated air gap in order to ventilate moisture that may occur. According to the manufacturer of the variable vapor barrier, the vented air gap will not be needed. By replacing the vented air gap with an additional layer of insulation the heating requirements of the building can be reduced which contributes to lower operating costs and reduced environmental impact.

 

The variable diffusion barrier has variable vapor permeability due to the relative humidity. In winter, the relative humidity is low, and the vapor diffusion barrier is vapor tight. During the summer, the relative humidity is high and the vapor permeability is increased within the diffusion barrier. A roof structure with variable diffusion barrier is based on the principle of moistening and drying of included material. A moisture transfer from the roof moistened part to the indoor air is possible when the roof's outer parts are heated by for example the sun.A dynamic calculation model has been designed to be able to analyze the temperature and moisture conditions of the roof with the module placed at different locations in Sweden.

 

By analyzing the results, the roofs moisture conditions have been revealed. Climate data such as solar radiation, relative humidity and temperature were taken into account.The weakest link in the structure is the chipboard which is located closest to the roof cover. By low moisture load, modeling results show that the investigated roof structure with variable diffusion barrier can be used in the southern part of Sweden. In northern Sweden, problems occur due to a colder climate with lower heat radiation from the sun. The roof structure shows a high risk of moisture damage, at high moisture load, regardless of location in Sweden.

Place, publisher, year, edition, pages
2012. , 37 p.
Keyword [sv]
fukt, ångspärr, diffusionsspärr, diffusion, mögel, tak, modulhus, temperatur, fuktskador
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:kau:diva-13565Local ID: BYI-21OAI: oai:DiVA.org:kau-13565DiVA: diva2:532545
External cooperation
Moelven Byggmodul AB
Subject / course
Building Engineering, Bachelor of Science
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-06-21 Created: 2012-06-11 Last updated: 2016-04-01Bibliographically approved

Open Access in DiVA

Fuktsäkerhet för takkonstruktion med variabel ångspärr(6289 kB)759 downloads
File information
File name FULLTEXT01.pdfFile size 6289 kBChecksum SHA-512
675919b32eac8093d76cdde689e09c24e77ee8acdbd53c14ffde80cd25b13d87f6fc5194e7759689d7677be5601ebaec089d0bfe24846b2b4dc9fbfe1936ec69
Type fulltextMimetype application/pdf

By organisation
Department of Energy, Environmental and Building Technology
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 759 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 506 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf