Analys av en kondenstorktumlares energi- och massbalans samt av möjligheterna för energieffektivisering
Karlstad University, Faculty of Technology and Science, Department of Energy, Environmental and Building Technology.
2012 (Swedish)Independent thesis Basic level (university diploma), 15 credits / 22,5 HE creditsStudent thesis
Abstract [sv]

Examensarbetet har utförts i samarbete med Asko Cylinda AB i syfte att analysera och förbättra en nyligen lanserad kondenstorktumlare från företaget. Rapporten har haft som mål att uppställa en mass-­‐ och energibalans över kondenstorktumlaren, där en analys av balanserna låg till grund för att hitta energibesparingsåtgärder. Maskinens ursprungliga prestanda undersöktes i laborationsförsök för att se hur prestandan sedan påverkades av ett isolerande material i anslutning av dess hölje. Särskilt intresse lades i att undersöka hur mycket värmeförlusterna kunde sänkas samt hur mycket mindre el som behövde tillföras till torktumlarens elelement när isolering användes. Vidare diskuteras ytterligare åtgärder som kan minska på maskinens energiförbrukning. Med hjälp av laboratorieförsök och termodynamiska beräkningar i kombination med masstekniska beräkningar visar rapporten på att en minskning av värmeförlusterna med upp till 73 % är möjlig då isolering gjord av cellplast används. Dessutom var det möjligt att förbruka 6 % mindre el då värmeelementet styrdes med en on/off reglering i kombination med användandet av isolering. I rapporten diskuteras möjligheterna för driftoptimering av fläktarna, användandet av andra ytmaterial samt möjligheterna för tätning som ytterligare förslag för att genomföra energibesparingsåtgärder. Resultaten anses vara tillämpbara på flertalet produktgrupper som tillverkaren Asko Cylinda AB producerar 

Abstract [en]

The thesis was conducted in collaboration with Asko Cylinda AB in order to analyze and improve a recently launched condensation dryer from the company. This report has aimed to establish a mass and energy balance over the condenserdryer, where an analysis of balances would to be the basis to find energy saving improvements. The machine’s initial performance was examined in laboratory tests to see how the performance would be affected by an insulating

material surrounding the dryer. Particular interest was spent in examining how much heat loss could be reduced and how much less electricity that needed to be brought into the dryers electric heater when insulation was used. Another aim of the thesis was to discuss the potential for additional measures that could reduce the machine's energy consumption. With the help of laboratory tests together with heat-­‐ and mass technical calculations, the report shows that a reduction in heat loss by up to 73 % is possible when a insulation made of foam was used. More over, it

was possible to consume 6 % less electricity when the heating element was controlled by an on / off control in combination with the use of insulation. The report discusses the possibilities for optimizing operation of the fans, the use of other surface materials and the possibility of efficient sealing as further proposals to implement energy saving measures. The results are considered to be applicable

to the majority of product groups that the manufacturer Asko Cylinda AB produces. 

Place, publisher, year, edition, pages
2012. , 37 p.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kau:diva-13485Local ID: EMI-14OAI: oai:DiVA.org:kau-13485DiVA: diva2:531203
Subject / course
Energy and Environmental Engineering, Bachelor of Science
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-06-21 Created: 2012-06-06 Last updated: 2012-06-21Bibliographically approved

Open Access in DiVA

Rapport(15380 kB)324 downloads
File information
File name FULLTEXT01.pdfFile size 15380 kBChecksum SHA-512
50693c6dce59561606585343241148dded121f83c056b919e47e4c26ebb3147eb18ae5a31211166dff31c8d157e8b24b21c5acedbec247c71c259d4322b5a6b4
Type fulltextMimetype application/pdf

By organisation
Department of Energy, Environmental and Building Technology
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 324 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 410 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf