Change search
ReferencesLink to record
Permanent link

Direct link
Second External Quality Assurance Study for the Serological Diagnosis of Hantaviruses in Europe
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Cell Biology.
Show others and affiliations
2012 (English)In: PLoS Neglected Tropical Diseases, ISSN 1935-2735, Vol. 6, no 4, e1607- p.Article in journal (Refereed) Published
Abstract [en]

Hantaviruses are endemic throughout the world and hosted by rodents and insectivores. Two human zoonoses, hemorrhagic fever with renal syndrome (HFRS) and hantavirus pulmonary syndrome (HPS), are caused by hantaviruses and case fatality rates have reached 12% for HFRS and 50% for HPS in some outbreaks. Symptomatic hantavirus infections in Europe are summarised as HFRS mainly due to Puumala, Dobrava-Belgrade and Saaremaa virus. While HFRS has an overall low incidence in Europe, the number of cases varies from 100 per year in all Eastern and Southern Europe up to 1,000 per year only in Finland. To assess the quality of hantavirus diagnostics, the European Network for the Diagnostics of 'Imported'' Viral Diseases (ENIVD) organised a first external quality assurance (EQA) in 2002. The purpose of this second EQA study is to collect updated information on the efficiency and accurateness of hantavirus serological methods applied by expert laboratories. A serum panel of 14 samples was sent to 28 participants in Europe of which 27 sent results. Performance in hantavirus diagnosis varied not only on the method used but also on the laboratories and the subclass of antibodies tested. Commercial and in-house assays performed almost equally. Enzyme immunoassays were mainly used but did not show the best performances while immunoblot assays were the less employed and showed overall better performances. IgM antibodies were not detected in 61% of the positive IgM samples and IgM detection was not performed by 7% of the laboratories indicating a risk of overlooking acute infections in patients. Uneven performances using the same method is indicating that there is still a need for improving testing conditions and standardizing protocols.

Place, publisher, year, edition, pages
2012. Vol. 6, no 4, e1607- p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-175218DOI: 10.1371/journal.pntd.0001607ISI: 000303496800023OAI: diva2:530938
Available from: 2012-06-05 Created: 2012-06-04 Last updated: 2012-06-05Bibliographically approved

Open Access in DiVA

fulltext(109 kB)77 downloads
File information
File name FULLTEXT01.pdfFile size 109 kBChecksum SHA-512
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Niklasson, Bo
By organisation
Department of Medical Cell Biology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 77 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 158 hits
ReferencesLink to record
Permanent link

Direct link