Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Biocompatibility tests performed on nanoporous aluminum oxide coated with polyethyleneglycol and titanium dioxide
Uppsala University, Disciplinary Domain of Science and Technology, Chemistry, Department of Chemistry - Ångström, Inorganic Chemistry.
2011 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Biokompatibilitetstester utförda på nanoporös aluminiumoxid belagd med polyeteylenglykol och titandioxid (Swedish)
Abstract [en]

Anodized aluminium oxide may be chemically treated to yield a uniform self-organized distribution of pores with a specific pore diameter. The thickness of in-house anodized alumina and its pore size can be modified by changing the electrolyte, the temperature of the electrolyte, the time of anodization and the potential over the anodized plates. 

In this thesis, a method for anodized aluminium oxide (AAO) was optimized for creating custom-made porous alumina membranes and coating them with TiO2 and polyethylene glycol (PEG). The purpose of finding a method to create porous alumina oxide with specific pore diameters was to eventually use these membranes for use in contact with human living tissue, allowing wanted nutrients and fluid to pass in and out.

     SEM images showed that a reproducible method has been established for the membrane production, where the pore diameter is ~ 300nm and the thickness of the oxide is approximately 100µm. The SEM images also showed that the pores are stable and uniform over the entire aluminum plate where they are initially produced.

     As a test for biocompatibility, the membranes were implanted into the hipbone of pigs.

The histology test showed fibrosis around the location where the membranes were placed. An observation during the extraction was swollenness in the surrounding tissue, which indicates inflammation around the implant. In this respect, the membranes cannot be used for the purpose intended.

Place, publisher, year, edition, pages
2011. , 23 p.
Series
UPTEC K, ISSN 1650-8297 ; 11039
Keyword [en]
Aluminum, polyethyleneglycol, titanium dioxide
National Category
Materials Engineering
Identifiers
URN: urn:nbn:se:uu:diva-168441OAI: oai:DiVA.org:uu-168441DiVA: diva2:497081
Subject / course
Material
Educational program
Master Programme in Chemical Engineering
Uppsok
Technology
Supervisors
Examiners
Available from: 2012-02-29 Created: 2012-02-10 Last updated: 2012-02-29Bibliographically approved

Open Access in DiVA

fulltext(2295 kB)584 downloads
File information
File name FULLTEXT02.pdfFile size 2295 kBChecksum SHA-512
5162dcef2e0f00e76030aa7b71245ef96cefa2e9bb34e1700b37f993b084a61b153c992481c2e02dca976551e69d48c3fab8c807def4605ab05a9c538dcc1dbf
Type fulltextMimetype application/pdf

By organisation
Inorganic Chemistry
Materials Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 584 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1017 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf