Investigation of Dielectric Response Measurement as a Tool to Detect Copper Sulphide on Insulation Paper
Norwegian University of Science and Technology, Faculty of Information Technology, Mathematics and Electrical Engineering, Department of Electrical Power Engineering.
2008 (English)MasteroppgaveStudent thesis
Abstract [en]
Several power transformers has, during the last two decades, broken down due to the copper sulphide problem. Corrosive sulphur reacts with the copper conductor contaminating the surrounding insulating paper. To this day there are no reliable nondestructive methods to detect copper sulphide contamination in a power transformer. Dielectric frequency measurement is a nondestructive tool used in the transformer industry. The measurements can give important information about the condition of the transformer insulation. In this master thesis the usage of dielectric frequency measurement as a tool to detect copper sulphide on insulation paper has been investigated. The task has been divided into two subtasks: • Subtask I: Develop and test different methods to create and classify copper sulphide contamination on paper samples. • Subtask II: Examine the dielectric frequency response of the contaminated samples as a function of copper sulphide Solution and results for Subtask I For sample creation two methods were used: • Creating samples out of paper strips taken from existing transformers • Growing copper sulphide on paper in the laboratory for three, ffve, eleven and fourteen days For copper sulphide classiffcation three methods were used: • Resistance measurement • Area percentage calculation • Classiffcation by the number of days grown. For sample creation the growth of copper sulphide samples seemed to be the better choice as the gaps between the samples of strips gave large uncertainties in the dielectric frequency response. The growth varied in some extent and days of growth some times became insuffcient in classifying degree of copper sulphide. Good connection between the copper and paper may be an important factor, and the size of the samples is recommended to be kept small. For all samples, contamination got heaviest at the edge. For the samples grown for fourteen days the paper became too fragile for dielectric frequency testing. The resistance measurement classiffcation method seemed to be the best choice, as it could cope with large variations in the contamination. The area percentage calculation method worked under very limiting conditions as the contamination had to be of a certain brightness level and with low variations in colour. The classiffcation due to days of growth came too short as the contamination between ffve and seven days were not that signiffcant. Larger time intervals can be a solution. Solutions and Results from Subtask II Dielectric frequency measurements were tested with two separate equipments: • The Insulation Diagnostic Analyser: Frequency range: 1mHz-1kHz • .The Alpha-Analyser: Frequency range: 100Hz-1MHz All tests where performed in equilibrium with air humidity at the time of testing. The gaps between the strips, used in the samples, gave a substantial effect to the dielectric frequency response. This effect was clearest at the lower frequencies, but some effect can also be seen in the higher region. At the lower frequencies the results gave no indication of any effect in the dielectric response due to copper sulphide. However, the gap effect may have concealed the effect, and testing without gaps is recommended. At the higher frequencies the grown copper sulphide samples gave some variations in the dielectric frequency response. The variations in results also occurred between samples with the same creation conditions. This may still indicate a relation between copper sulphide and dielectric response at higher frequencies. Even with the large deviations there were, at frequencies above 100kHz, a steeper increase in losses for the contaminated samples. Of the grown samples created only samples of ffve and seven days growth were tested. This gives a limited research foundation and further investigation is needed. Conclusions and Future Work In general there might be a correlation between copper sulphide and dielectric frequency measurement. Growing samples has turned out to work well as the test object provider. By combining days of growth with resistance measurements the classiffcation of the contamination should be suffcient. However, more research is absolutely needed and some suggestions for further work are as follows: • Dry the samples to minimise the water effect on the dielectric frequency measurement. • Creating a new smaller sample cell for the Insulation Diagnostic Analyser, so the sample size can be reduced and sample without gaps can be run in the lower frequency range. • Increase the time gap between the samples grown to get larger differences in contamination, and reduce the effect of variations. • Reducing the temperature may be a way to increase days of growth. However, in this case more research on the temperature dependencies of copper sulphide growth is needed.
Place, publisher, year, edition, pages
Institutt for elkraftteknikk , 2008. , 83 p.
Keyword [no]
ntnudaim:4157, MIENERG energibruk og energiplanlegging, Elektrisk energiteknikk
URN: urn:nbn:no:ntnu:diva-12876Local ID: ntnudaim:4157OAI: diva2:426916
Available from: 2011-06-27 Created: 2011-06-27

Open Access in DiVA

fulltext(9866 kB)1927 downloads
File information
File name FULLTEXT01.pdfFile size 9866 kBChecksum SHA-512
Type fulltextMimetype application/pdf
cover(46 kB)33 downloads
File information
File name COVER01.pdfFile size 46 kBChecksum SHA-512
Type coverMimetype application/pdf

By organisation
Department of Electrical Power Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1927 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 267 hits
ReferencesLink to record
Permanent link

Direct link