Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Measurement and validation of urinary cystatin C by particle-enhanced turbidimetric immunoassay on Architect ci8200
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Biochemistry and Microbiology.
2011 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Cystatin C, a 13 kDa low molecular weight protein is an inhibitor of cysteine proteases. Due to its low molecular weight and positive charge at physiological pH, it is freely filtered by the glomerulus and catabolized after reabsorption by proximal tubular cells with a low concentration (0.03-0.3 mg/L) in urine amongst healthy subjects. Urinary cystatin C is a potential biomarker detection of acute kidney injury (AKI) in the acute phase when patients are submitted to the intensive care unit. The aim in this report was to perform a full method validation of urinary analysis of cystatin C on a high throughput chemical analyzer by particle-enhanced turbidimetric immunoassay (PETIA) at the University Hospital in Uppsala, Sweden. The antigen excess, linearity, lower limit of quantification (LoQ), recovery, assay precision, stability and interference caused by haemoglobin was evaluated. No hook effect was observed, the assay was linear over the studied interval <0.001-0.950 mg/L with a regression of R2=0.9994. The LoQ was calculated to 0.020 mg/L with a coefficient of variation (CV) ≤10% which was considered acceptable. The assay had a recovery between 93-100% and the assay precision had a total CV <3.5%. Cystatin C is stable for 3 days in room temperature and 14 days in +4C. The assay did not show any major interference with haemoglobin. The urinary cystatin C showed good precision and performance characteristics by measurements using PETIA all of which is a necessary qualification for a biomarker at a 24-h running routine laboratory.

Place, publisher, year, edition, pages
2011. , 9 p.
Keyword [en]
avian antibodies, cystatin C, method validation, particle-enhanced turbidimetric immunoassay, urine
National Category
Other Clinical Medicine
Identifiers
URN: urn:nbn:se:uu:diva-154713OAI: oai:DiVA.org:uu-154713DiVA: diva2:421915
Educational program
Biomedicinska analytikerprogrammet
Uppsok
Medicine
Supervisors
Examiners
Available from: 2011-06-10 Created: 2011-06-09 Last updated: 2011-06-10Bibliographically approved

Open Access in DiVA

fulltext(276 kB)364 downloads
File information
File name FULLTEXT01.pdfFile size 276 kBChecksum SHA-512
2da4e00efdd2a71cfde48af9a4c1dd4aca80945b19b1efc0775fedd491e01fe33e9241230b308f326463004139b42850a47dbc879e53e018e3af4f405e535ca7
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Hikmet Noraddin, Feria
By organisation
Department of Medical Biochemistry and Microbiology
Other Clinical Medicine

Search outside of DiVA

GoogleGoogle Scholar
Total: 364 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 592 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf