Change search
ReferencesLink to record
Permanent link

Direct link
Moneo: Säkert varningssystem för detektering vid infiltration
Halmstad University, School of Business and Engineering (SET).
Halmstad University, School of Business and Engineering (SET).
2011 (Swedish)Independent thesis Basic level (degree of Bachelor), 15 credits / 22,5 HE creditsStudent thesisAlternative title
Moneo: IV Infiltration Detection System (English)
Abstract [sv]

I Sverige drabbas varje år mer än 150 barn av allvarliga skador under infusionsbehandling.

I nära samarbete med Hallands sjukhus Halmstad och har ett varningssystem utvecklats för att detektera infiltration under infusionsbehandling. Detta är en produkt som efterfrågats i 30 år av barnläkaren och idéskaparen till projektet, Kent-Åke Henricson. Infiltration är en medicinsk term som beskriver när infusionsvätska läcker ut i omgivande vävnad runt blodvenen. Beroende på vilket läkemedel som infiltrerats kan skadans allvarlighetsgrad variera från en lätt hudreaktion till allvarlig nekros. Vid en allvarlig infiltration förlängs vårdtiden vilket blir kostsamt för sjukhusen.

Moneo underlättar arbetet för sjukvårdspersonal likaså ger det barn en trygg och säker behandling. Idag görs rutinkontroller av sjuksköterska upp till varannan timme på droppets insticksställe, vilket är både tidskrävande och störande för patienten. Produkten fungerar som ett kompletterande stöd vid behandling och är anpassad för att användas med befintlig infusionsutrustning.

Barn är aktiva patienter och produkten är utformad för att tillåta fysiska rörelser och genom sin lätta vikt och smarta konstruktion är produkten bekväm för patienten och enkel att integrera i sjukvårdspersonalens rutiner.

Projektgruppen är stolt och nöjd över att presentera sitt examensarbete Moneo, som resulterat i en produkt som ger säkrare vård och förhindrar onödigt lidande för barn. Ingen patient ska behöva skadas i vården, det är en grundprincip för all vårdverksamhet.

Abstract [en]

Each year more than 150 children suffer from severe injuries during IV infusion therapy in Sweden.

In close cooperation with Hallands sjukhus Halmstad, a new warning system has been developed for detection of infiltration during IV infusion. For more than 30 years this kind of product has been requested from pediatrician and innovator Kent- Åke Henricson. Infiltration is a medical term used to describe when you infuse medical drugs into the surrounding tissue instead of into the vein. Depending on the type of medicine that has been infiltrated, the severity of the injury varies from light skin reaction to severe necrosis. A severe infiltration leads to extended hospital stays for the patient, which can be costly for the hospital.

Today a nurse does regular checkups every two hours at the puncture site in order to insure that the medicine is being delivered properly. This is very time consuming for medical staff, as well as, annoying for the patient. Our product will function as an additional safe guard during infusion therapy and is adapted to be used with existing infusion devices. Moneo allows for easier monitoring by medical staff while giving children a more safe treatment.

Children are active patients and Moneo’s light weight and smart design allows for physical movement and comfort of the patient. It is also easily integrated into the existing procedures and routines of the medical professionals.

The project group is proud and happy to present their final thesis, Moneo, which has resulted in a product that can eliminate unnecessary suffering in the children receiving IV infusion therapy thereby providing a more safe treatment option. It is a basic medical principle that no patient should suffer negative side effects of a medical procedure. Moneo can be used to avoid these kinds of concerns.

Place, publisher, year, edition, pages
2011.
Keyword [sv]
moneo, varningssystem, infusion
Identifiers
URN: urn:nbn:se:hh:diva-15255OAI: oai:DiVA.org:hh-15255DiVA: diva2:420843
Subject / course
Development
Uppsok
Technology
Supervisors
Examiners
Available from: 2011-06-22 Created: 2011-06-06 Last updated: 2011-06-22Bibliographically approved

Open Access in DiVA

rapport(10408 kB)288 downloads
File information
File name FULLTEXT01.pdfFile size 10408 kBChecksum SHA-512
939e75d46d86766a3f66558ccb874d7d6387691c7e515a32803fde6c58a92550e4a5070b319a314278d9097912b0307ac6ec8e22752a0e84f15570a8c3c8de47
Type fulltextMimetype application/pdf

By organisation
School of Business and Engineering (SET)

Search outside of DiVA

GoogleGoogle Scholar
Total: 288 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available