Möjligheter att kontrollera damning från fasta bränslen genom kemisk behandling
KTH, School of Industrial Engineering and Management (ITM), Industrial Ecology.
2005 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [sv]

Igelsta fjärrvärmeverk producerar med till största delen bio- och returbränslen, värme till cirka200 000 människor i södra Stockholm. Att använda fasta bio- och returbränslen minskar dentotala miljöbelastningen jämfört med fossila bränslen men skapar lokala miljöproblem pågrund av bland annat damning. Damning är ett stort lokalt miljöproblem på Igelstaverket ochorsakar risker för dammexplosioner samt olägenheter i omgivningen.

Detta projekt har undersökt möjligheterna att minska damningen från ett urval av de fastabränslen som används på Igelstaverket, genom behandling med dammreduceringskemikaliervid sidan av de mekaniska åtgärderna. Fyra dammreduceringskemikalier valdes ut för att ilabbskala testas på sex av de mest utnyttjade bränslena på Igelstaverket. PiniDust ME som ärett dammbindande medel var den dammreduceringskemikalie som i laborationerna, allmäntvisade bäst effekter med avseende på en direkt minskning av dammet, vid upprepadbehandling samt för varaktighet.

I projektet utfördes även test i pilotskala. Dessa skilde sig från laborationsförsöken genom attinte endast kemikalien längre påverkar dammreduceringen utan att också systemetsutformning påverkar vilken typ av damm som kan minskas. Dammätningar utfördes både föreoch under kemikaliebehandlingen i närheten av tre olika hanteringspunkter.Undersökningarna med behandling genomfördes med hjälp av ett dimsystem på bränslekross,skumsystem vid transport av returflis samt behandling av torvpellets vid skruvfickan på kajen.

Av de tre testade utrustningarna är det endast dimsystemets behandling på bränslekross somuppvisade en minskning av dammkoncentrationerna i luften, medan en behandling medskumsystemet inte uppvisade någon skillnad i dammhalter alls. Testet i pilotskala medPiniDust ME, som annars var den bästa kemikalien vid labbskaleförsöken, måste avbrytas pågrund av att systemets kapacitet inte var tillräckligt i förhållande till det bränsleflöde somhanteras på kajen. Dock är både kemikalien och systemet de överlägset dyraste, varför dekanske ändå inte skulle vara lönsamma att använda på anläggningen i längden.

I övrigt påvisade de fullskaliga försöken nackdelar som bör tas i beaktande vid enkemikaliebehandling. För att överhuvudtaget få någon nytta av kemikalierna genom etteffektivt fungerande system bör anordningar för värme samt väderskydd användas samtidigtsom en behandling. Vidare kräver ett system också personal som ansvarar för underhåll samtatt tillräckligt med kemikalier finns att tillgå vid behov.

Eftersom testerna utfördes under vintertid, då damningen på Igelstaverket är som lägst, skulletydligare resultat kanske kunna erhållas då vidare undersökningar genomfördes under andraårstider t.ex. våren eller hösten. Det kunde även vara värt att undersöka hur en behandling hosleverantören samt upprepade kemikaliehandlingar påverkar dammkoncentrationerna påIgelstaverket.

Abstract [en]

Igelsta district heating power plant produces heat, with mainly bio- and recycled fuels, toabout 200 000 people in the south of Stockholm. By using solid bio- and recycled fuels thetotal environmental effects are reduced, but local environmental effects include among othersairborne dust accumulation. Dust accumulation is a large local environmental problem atIgelsta power plant which constitutes risks for dust explosions and other inconveniences in theenvironment.

This project has investigated the possibilities to reduce the dust, originating from solid bioandrecycled fuels commonly used at Igelsta power plant, by chemical treatment in addition tomechanical measures. Four dust suppression chemicals were at first chosen in the treatment ofsix of the most used fuels at Igelsta power plant, for small-scale tests in the laboratory.PiniDust ME which is a dust binder, proved to be the dust reduction chemical that in generalshowed the best effects considering direct dust suppression, repeated treatment and longlasting effect.

Also pilot-scale tests were performed in the project on site. These experiments diverged fromthe laboratory tests because it is not only the chemical that affects the dust reduction, but alsothe design of the treatment system itself that influence what kind of dust that is controllable.Dust measurements were completed, both before and during the chemical treatments, close tothe three chosen different places where the bio-fuels were handled. The investigations withchemical treatment were carried out by a fogging system on waste fluff, foaming system onrecycled wood chips and treatment of peat pellets on the pocket of the quay where the fuels isfed into the transport line.

Of the three tested equipments, only the fogging system gave a reduction of the dustconcentrationsin the waste fluff, while a treatment with the foaming system did not revealany difference in dust concentrations in the air. The pilot-scale test with PiniDust ME, whichwas the chemical with the best characteristics in the laboratory tests, had to be terminatedduring the survey. The cause to this is the treatment system that did not have the sufficientcapacity in relation to the fuel flow that is handled in the harbour. However, both the chemicaland the system are by far the most expensive alternative, why it anyway maybe not would beprofitable to use in the long run.

In other respects, the pilot-scale tests exposed some drawbacks that are necessary to take intoconsideration when utilizing chemical treatment. On the whole, to make use of chemicaltreatment through an effectively functioning system, there is a need of an installation for heatand wind that should be used simultaneously during a treatment period. Further on, a systemalso requires personnel that are responsible for the service of the system and that the chemicalis readily available when needed.

Since the tests were performed during winter-time, when the dust accumulation is at itslowest, better results can be achieved if further investigations would be completed duringother seasons e.g. spring or autumn. It could also be interesting to observe how a treatmentalready at the suppliers place or repeated treatments also on site could affect the dustconcentrations at the area of Igelsta district heating power plant.

Place, publisher, year, edition, pages
2005. , 75 p.
Series
Trita-IM, ISSN 1402-7615 ; 2005:5
National Category
Social Sciences Interdisciplinary
Identifiers
URN: urn:nbn:se:kth:diva-32673OAI: oai:DiVA.org:kth-32673DiVA: diva2:411372
Uppsok
Technology
Supervisors
Note
www.ima.kth.seAvailable from: 2011-04-28 Created: 2011-04-18 Last updated: 2011-04-28Bibliographically approved

Open Access in DiVA

fulltext(1081 kB)327 downloads
File information
File name FULLTEXT01.pdfFile size 1081 kBChecksum SHA-512
0f4f21fab10b678a5d390bf44e91959c6cda137ae5b106ffa022fc819cf13844910290cc38956a50fa6734d3e7330cf709896205075ea5b0aeb34f4061434648
Type fulltextMimetype application/pdf

By organisation
Industrial Ecology
Social Sciences Interdisciplinary

Search outside of DiVA

GoogleGoogle Scholar
Total: 327 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 122 hits
ReferencesLink to record
Permanent link

Direct link