Change search
ReferencesLink to record
Permanent link

Direct link
Screening of spill and leakage of antibiotics in hospital wards
Umeå University, Faculty of Science and Technology, Department of Chemistry.
Umeå University, Faculty of Science and Technology, Department of Chemistry.
2011 (English)In: Journal of ASTM International, ISSN 1546-962X, Vol. 8, no 6, 24- p.Article in journal (Refereed) Published
Abstract [en]

This paper presents a two-phase study of spill and leakage of antibiotics in hospitals. The first phase was a screening of spill and leakage at 21 hospital wards in 16 hospitals. Phase two was an extended investigation, where different measures to reduce spill and leakage were implemented and a follow-up screening was made to evaluate the effect of the measures. At the screening, 206 samples were collected. The result was used to classify the wards into four classes: Low, Mean, High, and Very high. Spatial distribution patterns and the effect of compounding systems were also investigated. The screening showed that spill and leakage occur at all wards. Eleven of the 21 wards had High or Very high contamination level. This result also showed that the substances were distributed according to three possible patterns. The compounding systems also had an impact on the spill and leakage. All four wards that used a closed system were found among the six wards with the lowest spill and leakage, while all three wards that used open venting systems were found among the six wards with the highest spill and leakage. The result also showed that it is possible to handle antibiotics with only insignificant spill and leakage, i.e., by using closed systems. Three wards, classified as Very high, were included in the second phase. Measures to decrease spill and leakage and reduce the distribution the substances were implemented. After two month, a follow-up screening was carried out. The result showed lower contamination levels at all three wards and the implemented measures had some effect. Simple and easy-to-do measures can contribute to reduce the spill and leakage that occur. There is still, however, a need to discuss how to handle antibiotics in a safe way to reduce possible spill and leakage and to prevent the distribution of this spill and leakage.

Place, publisher, year, edition, pages
ASTM International , 2011. Vol. 8, no 6, 24- p.
Keyword [en]
antibiotics, compounding, hospital wards, leakage, occupational exposure, screening, spill, surface contamination, wipe sampling
Identifiers
URN: urn:nbn:se:umu:diva-42416DOI: 10.1520/JAI103453OAI: oai:DiVA.org:umu-42416DiVA: diva2:409211
Available from: 2011-04-07 Created: 2011-04-07 Last updated: 2011-08-25Bibliographically approved

Open Access in DiVA

fulltext(724 kB)413 downloads
File information
File name FULLTEXT02.pdfFile size 724 kBChecksum SHA-512
1689b40a386c52d4c11e2a823b450b2fb4270f4a6816141a70918ac40a4c205bd5ad53c69bb69ce7612e73ec8330ad365893f5700bb748f70c5b4f820ab73ebe
Type fulltextMimetype application/pdf

Other links

Publisher's full textASTM

Search in DiVA

By author/editor
Nygren, OlleLindahl, Roger
By organisation
Department of Chemistry
In the same journal
Journal of ASTM International

Search outside of DiVA

GoogleGoogle Scholar
Total: 414 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 183 hits
ReferencesLink to record
Permanent link

Direct link