Change search
ReferencesLink to record
Permanent link

Direct link
Energy consumption of manufacturing line with special emphasis on lighting system
Mälardalen University, School of Sustainable Development of Society and Technology.
2011 (English)Independent thesis Advanced level (degree of Master (Two Years)), 30 credits / 45 HE creditsStudent thesis
Abstract [en]

The main focus of this project is to investigate the energy consumption of the manufacturing lines in the car industry and look for the potential methods regarding energy saving. Special emphasis is put on the lighting technologies that can be used in the manufacturing processes.

Two lighting technologies are tested in order to see which one has better performance and lower energy consumption. Fluorescent tube and LED tube are compared concerning illuminance, UV irradiance and power consumption. Economic evaluation is also conducted to exam the feasibilities replacing fluorescent tubes with LED tubes. Results of the study show that the LED tubes have much lower energy consumption than fluorescent tubes, produce more direct and „colder“ light, and have much lower UV irradiance. However, the payback period of LED is relatively long at current price situation. Since it is expected that the price of LED tubes will decrease in future, it is reasonable to predict that the LED technology will change the fluorescent one in many applications.

The energy consumption has been estimated for two manufacturing lines which use different technologies to produce car underbodies. In order to identify the differences from the energy consumption point of view, some measurements are conducted, such as the consumption of electricity, compressed air, air for ventilation and cooling water. The measured results show a disproportion in the power consumption when the lines are in stand-by mode. This affects the energy consumption per produced unit significantly. The line that has a higher capacity and a lower power consumption in the stand-by mode has a lower energy consumption per produced unit when it is operating with lower production loading. So, in order to improve the energy efficiency, it is necessary that it works at as high volume as possible and to have the stand-by power consumption as low as possible.

Place, publisher, year, edition, pages
2011. , 100 p.
Keyword [en]
energy consumption, measurements, car manufacturing line, lighting system, LED lamps, fluorescent lamps
Identifiers
URN: urn:nbn:se:mdh:diva-11980OAI: oai:DiVA.org:mdh-11980DiVA: diva2:404273
Uppsok
Technology
Examiners
Available from: 2011-03-25 Created: 2011-03-16 Last updated: 2011-03-25Bibliographically approved

Open Access in DiVA

fulltext(2513 kB)449 downloads
File information
File name FULLTEXT01.pdfFile size 2513 kBChecksum SHA-512
0eba02617d6822ad8d7b6d4fed561107031b0a729e3f4f2253a0875ebad3c0781642fe8a53484ff66bb1427a7f574e24fe4785acb215e6807cf060bb03c790d0
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Saršon, Bruno
By organisation
School of Sustainable Development of Society and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 449 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available