Kvarteret Kajutan - från lågenergi till plusenergi
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering.
2010 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
A study of a low energy house - methods for improvning energy performance while maintaining cost efficiency (Swedish)
Abstract [sv]

 

diskuterats flitigt, såväl på det nationella planet som på EU-nivå. Trenden pekar på ett

byggande där allt större vikt läggs vid den byggda miljöns energiprestanda. Redan i

dagsläget finns flera exempel på hus med ett mycket lågt energibehov, och antalet

lågenergihus växer för varje år.

I skrivande stund ligger kraven på bostäders specifika energianvändning på 110 kWh/m

2

år i Stockholm, men redan till nästa år finns förslag på att minska motsvarande siffra till

90. Energimyndigheten genomför just nu ett arbete med att tolka EU:s direktiv om så

kallade Nära nollenergihus och de preliminära resultaten indikerar att kravnivån för köpt

energi kommer hamna kring 55 kWh/m

2 år, vilket är i nivå med de rekommendationer

som i dag återfinns i FEBY:s Kravspecifikation för Passivhus.

Med utgångsläge i ett uppfört lågenergihus i Henriksdalshamnen i Stockholm har vi i

arbetet analyserat olika energieffektiviserande åtgärders inverkan på effekt- och

energibehov. Även de ekonomiska aspekterna förknippade med åtgärderna har studerats

med hjälp av en modell för livscykelkostnader.

Åtgärderna studerades inledningsvis individuellt för att ge en bild av hur stor påverkan de

har var för sig. Tre åtgärdspaket sattes sedan samman, där de mest energi- och

kostnadseffektiva lösningarna ingick.

Det första åtgärdspaketet syftade till att ta huset till passivhusnivå, vilket uppnåddes

genom byte av fönster samt en förbättring av lufttätheten. Den ekonomiska analysen

visade att detta paket inte var lönsamt. Det andra åtgärdspaketet hade som mål att så

mycket som möjligt sänka byggnadens energibehov och samtidigt uppvisa lönsamhet.

Resultatet blev ett mer än halverat energibehov och den ekonomiska kalkylen pekade på

att det även gick med vinst.

Slutligen studerades möjligheten att installera energiproducerande system för att kunna ta

huset till ett plusenergiutförande. Tanken var att undersöka om det var möjligt att på ett

ekonomiskt försvarbart sätt täcka upp behovet av köpt energi med hjälp av sol- och

vindkraft. Analysen visar att det i dagsläget skulle vara svårt att uppnå, främst på grund

av de stora investeringskostnader som åtgärderna medför, samt de hinder som är

förknippade med regelverken för att sälja energi.today’s recommendations found in FEBY's Kravspecifikation för

Passivhus.

 

 

Abstract [en]

Abstract

Energy and environmental demands regarding buildings have become an increasingly

discussed topic, both in Sweden and in Europe as a whole. The general trend indicates

that greater efforts are being put into the energy efficiency of the built environment.

There are already numerous examples of houses with a low energy demand, and the

number of low energy buildings is constantly growing.

At the time being, the maximum level for energy demands for housing in Stockholm is

110 kWh/m

2 year, but as soon as next year the limit will be changed to 90. The Swedish

agency Energimyndigheten is currently conducting a project to interpret the EU Directive

on the so-called Nearly zero energy buildings, and the preliminary results indicate that

the level of requirements for purchased energy will end up with about 55 kWh / m

2 year,

which is in line with

today’s recommendations found in FEBY's Kravspecifikation för

Passivhus.

Starting with a low-energy house in Henriksdalshamnen in Stockholm, we have analyzed

various energy-efficiency measures and their influence on power and energy needs. The

financial aspects associated with the measures have been studied using a model of life

cycle costs.

The measures were initially studied individually to give an idea of how much impact they

each had. Three packages of measures were then put together, where the most energyand

cost-effective solutions were included.

The first package of measures aimed to achieve the standard for Passive houses, and was

accomplished by the replacement of windows and an improvement in airtightness. The

economic analysis showed that this package was not viable. The second package of

measures aimed to as much as possible reduce the building's energy needs and at the

same time demonstrate profitability. The results showed a more than halved energy

demand and the economic calculations indicated that it even turned a profit.

Finally, the possibility of installing energy-producing systems in order to achieve a plus

energy house was studied. The idea was to examine whether it was possible to cover up

the need for purchased energy by using solar and wind power, while maintaining

profitability. The analysis shows that this would be difficult to achieve, primarily because

of the high investment costs entailed, and the difficulties associated with the regulations

regarding the sale of energy.

Place, publisher, year, edition, pages
2010. , 74 p.
Series
Examensarbete Byggnadsteknik, Nr 406
Keyword [sv]
passivhus, lågenergihus, plusenergihus, energibesparing, LCC
Identifiers
URN: urn:nbn:se:kth:diva-31444OAI: oai:DiVA.org:kth-31444DiVA: diva2:404035
Uppsok
Technology
Supervisors
Examiners
Available from: 2011-03-28 Created: 2011-03-15 Last updated: 2011-03-28Bibliographically approved

Open Access in DiVA

fulltext(1618 kB)138 downloads
File information
File name FULLTEXT01.pdfFile size 1618 kBChecksum SHA-512
0416016832fb62a602bcc520dd0f54a599316fe475b57fea748fa2f5327c55132d60db4cc406090174070ed1e95994544fab14bd1efd02db3a4807178ff3ea9a
Type fulltextMimetype application/pdf
fulltext(1618 kB)536 downloads
File information
File name FULLTEXT02.pdfFile size 1618 kBChecksum SHA-512
0416016832fb62a602bcc520dd0f54a599316fe475b57fea748fa2f5327c55132d60db4cc406090174070ed1e95994544fab14bd1efd02db3a4807178ff3ea9a
Type fulltextMimetype application/pdf

By organisation
Civil and Architectural Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 674 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 239 hits
ReferencesLink to record
Permanent link

Direct link