Comparing fMRI Activity Maps from GLM and CCA at the Same Significance Level by Fast Random Permutation Tests on the GPU
Linköping University, Department of Biomedical Engineering, Medical Informatics. Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, The Institute of Technology.
Linköping University, Department of Biomedical Engineering, Medical Informatics. Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, The Institute of Technology.
Linköping University, Department of Biomedical Engineering, Medical Informatics. Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, The Institute of Technology.
Linköping University, Department of Biomedical Engineering, Medical Informatics. Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, The Institute of Technology.ORCID iD: 0000-0002-9091-4724
2011 (English)Conference paper (Other academic)
Abstract [en]

Parametric statistical methods are traditionally employed in functional magnetic resonance imaging (fMRI) for identifying areas in the brain that are active with a certain degree of statistical significance. These parametric methods, however, have two major drawbacks. First, it isassumed that the observed data are Gaussian distributed and independent; assumptions that generally are not valid for fMRI data. Second, the statistical test distribution can be derived theoretically only for very simple linear detection statistics. In this work it is shown how the computational power of the Graphics Processing Unit (GPU) can be used to speedup non-parametric tests, such as random permutation tests. With random permutation tests it is possible to calculate significance thresholds for any test statistics. As an example, fMRI activity maps from the General Linear Model (GLM) and Canonical Correlation Analysis (CCA) are compared at the same significance level.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press , 2011.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:liu:diva-66206OAI: oai:DiVA.org:liu-66206DiVA: diva2:402372
Conference
SSBA Symposium on Image Analysis, March 17-18, Linköping, Sweden
Available from: 2011-03-08 Created: 2011-03-08 Last updated: 2013-08-28Bibliographically approved

Open Access in DiVA

fulltext(213 kB)693 downloads
File information
File name FULLTEXT01.pdfFile size 213 kBChecksum SHA-512
46fc00ccc4b4bb16599aa8e137d0f05029e60a41bef845cadc57e98d5239bb54aca69d17157716de711e96e0695d67102d45132e402d2afad31cec7101d19642
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Eklund, AndersFriman, OlaAndersson, MatsKnutsson, Hans
By organisation
Medical InformaticsCenter for Medical Image Science and Visualization (CMIV)The Institute of Technology
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 693 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 475 hits
ReferencesLink to record
Permanent link

Direct link