Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The reproducibility of protocols used to mediate a current-induced vasodilation in the human cutaneous microcirculation
Univ Grenoble Alpes, CHU Grenoble Alpes, INSERM, U1300,HP2, Grenoble, France.;Univ Grenoble Alpes, CHU Grenoble Alpes, INSERM, CIC1406, Grenoble, France..ORCID iD: 0000-0002-7203-8134
Univ Grenoble Alpes, CHU Grenoble Alpes, INSERM, CIC1406, Grenoble, France..ORCID iD: 0000-0002-4305-3300
Univ Grenoble Alpes, CHU Grenoble Alpes, INSERM, U1300,HP2, Grenoble, France.;Univ Grenoble Alpes, CHU Grenoble Alpes, INSERM, CIC1406, Grenoble, France..
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Clinical Epidemiology. Univ Grenoble Alpes, CHU Grenoble Alpes, INSERM, U1300,HP2, Grenoble, France..ORCID iD: 0000-0001-5623-7478
2024 (English)In: PLOS ONE, E-ISSN 1932-6203, Vol. 19, no 11, article id e0314430Article in journal (Refereed) Published
Abstract [en]

Introduction: Current-induced vasodilation (CIV) can be used to assess the prostacyclin (PGI(2)) pathway. This study, for the first time, evaluated the reproducibility of several protocols used to mediate a CIV.

Methods: Three CIV protocols were evaluated in 10 healthy participants who completed four testing sessions. Two testing sessions were conducted on the calf, separated by a period of seven days allowing interday reproducibility to be assessed. Two testing sessions were also conducted seven days apart on the forearm. At each testing session, cutaneous microvascular assessments were conducted for one hour on the right limb of interest before assessments were immediately performed on the left limb, allowing for intersite, intraday reproducibility to be evaluated. Assessments were then repeated at the same site on the right limb, allowing for intrasite, intraday reproducibility to be evaluated. Reproducibility was assessed using the within-subject coefficients of variation and the intra-class correlation coefficients.

Results: Protocol A (Pulses of 0.03, 0.06, 0.09, 0.12, 0.15, and 0.18 mA for 10 s each; 60 s intervals), Protocol B (0.1 mA for 60 s), and Protocol C (2 pulses of 0.1 mA for 10s each; 240 s interval) had good to excellent interday reproducibility for calf and forearm assessments. The intrasite, intraday reproducibility of each protocol was less clear. Intersite testing didn't improve intraday reproducibility. Reproducibility was consistently unacceptable when the microvascular response to the electrical stimulation was expressed as the absolute change and the percentage change between baseline values and the maximal plateau. A microvascular response wasn't induced similar to 10% of assessments on either the calf or forearm.

Conclusions: This study indicates that a CIV is most reproducible with interday testing and when data are expressed as the maximal plateau in perfusion units or as cutaneous vascular conductance, and as the area under the curve.

Place, publisher, year, edition, pages
Public Library of Science (PLoS), 2024. Vol. 19, no 11, article id e0314430
National Category
Clinical Medicine
Identifiers
URN: urn:nbn:se:uu:diva-550561DOI: 10.1371/journal.pone.0314430ISI: 001408424400055PubMedID: 39602483Scopus ID: 2-s2.0-85210985073OAI: oai:DiVA.org:uu-550561DiVA, id: diva2:1938201
Funder
EU, Horizon 2020, 898829Available from: 2025-02-17 Created: 2025-02-17 Last updated: 2025-02-28Bibliographically approved

Open Access in DiVA

fulltext(1123 kB)26 downloads
File information
File name FULLTEXT01.pdfFile size 1123 kBChecksum SHA-512
19afcda2f80be501ae231636afa9aaac5805af201a5855aa9b9e54e294817fe00783f699796b7e1790d1f89a9946743de61c0e9d4d09779037e364f95cf27b54
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Guigui, AliciaLiaigre, LeaLoader, Jordan
By organisation
Clinical Epidemiology
In the same journal
PLOS ONE
Clinical Medicine

Search outside of DiVA

GoogleGoogle Scholar
Total: 26 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 259 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf