Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Jämförelsestudie: mätning av luftkvalitet och upplevd luftkvalitet
KTH, School of Industrial Engineering and Management (ITM).
KTH, School of Industrial Engineering and Management (ITM).
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

På uppdrag av REQS som en del i deras projekt “IOTs möjligheter till bättre besiktningar och kontroller i fastigheter och byggnader” skulle mätdatan från deras speciellt framtagna sensorer jämföras med uppfattningen av luftkvaliteten i lokalerna där dessa är placerade. Syftet var att undersöka huruvida bra mätdata kunde garantera om luften upplevdes som positiv samt gav upphov till god hälsa. Sensorerna mätte temperatur, relativ luftfuktighet och TVOC, samt gav även ut en ekvivalent koldioxidhalt.

En litteraturstudie gjordes för att undersöka betydelsen av dessa nyckeltal samt effekten de har på människan. I en tabell sammanställdes riktvärden och rekommendationer på de olika mätvärdena och dess eventuella symptom och biverkningar listades i de fall rekommendationerna överträddes.

Intervjufrågor skrevs varpå intervjuer genomfördes på tre olika företag. De intervjuade personerna fick svara på frågor om deras allmänna uppfattning gällande luftkvalitet och temperatur, samt även om de upplever symptom som huvudvärk, trötthet, torrhet etc. Från samma lokaler togs sedan mätdatan från sensorerna. Denna mätdata jämfördes med resultaten från intervjuerna och det diskuterades vilka slutsatser och samband som kunde ses. Nedan är slutsatserna kortfattat:

● Resultatet i denna studie visar på att majoriteten av personalen är nöjd med luftkvaliteten när nyckeltalen håller sig inom riktvärdena.

● Temperaturen är avgörande för uppfattningen av luftkvaliteten. Överstiger temperaturen 25 °C kommer luftkvaliteten upplevas som dålig oavsett hur ren luften är. Förhöjd temperatur leder även till symptom som huvudvärk och trötthet.

● En relativ luftfuktighet under 20 % kommer leda till att en del av personalen upplever torrhet.

● Obehag som drag och nackspärr uppkommer trots att nyckeltalen uppvisar goda resultat. Det går alltså inte att säkerställa en dragfri miljö med hjälp av sensorerna.

Abstract [en]

This study was made at the request of REQS as a part of their project “IOTs möjligheter till bättre besiktningar och kontroller i fastigheter och byggnader”. Data from their specially developed sensors was compared with the perception of the air quality in the locations where the sensors were placed. The purpose was to investigate whether how good data could guarantee a positive perception of the indoor climate and ensure good health. The sensors recorded temperature, relative humidity and TVOC, and it also presented equivalent carbon dioxide.

A literature study was completed to evaluate the significance and effect these key values have on the human. Recommendations and requirements regarding the air quality was compiled into a table, where the eventual symptoms and side effects was listed in case the recommendations were violated.

Interview questions were written, whereupon interviews were conducted at three different companies. The interviewees were to answer questions regarding their general opinion of the air quality and temperature, as well as if they experienced some kind of symptom like headache, tiredness, dryness etc. The sensor data was later collected from the same location. This data was compared to the interview results, and eventual conclusions were discussed. Below are the conclusions presented briefly:

● The result in this study shows that the majority of the employees are satisfied with the air quality when the sensor data is satisfactory.

● The temperature is decisive for the opinion of the air quality. If the temperature rises above 25 °C the air quality will be experienced as bad, no matter how clean the air actually is. Increased temperature will also result in symptoms like headache and tiredness.

● A relative humidity below 20 % will result in some experience of dryness among the employees.

● Discomfort such as breeze and stiff neck occur despite the sensor data is satisfactory. A calm environment can thereby not be guaranteed with the help of the sensors.

Place, publisher, year, edition, pages
2019. , p. 38
Series
TRITA-ITM-EX ; 2019:319
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-264531OAI: oai:DiVA.org:kth-264531DiVA, id: diva2:1373967
Supervisors
Examiners
Available from: 2019-11-28 Created: 2019-11-28 Last updated: 2019-11-29Bibliographically approved

Open Access in DiVA

fulltext(2505 kB)2 downloads
File information
File name FULLTEXT01.pdfFile size 2505 kBChecksum SHA-512
a32fe14ac123817c1a1f8dae9bdb093450cea6677fa86019353c87014983a24e1cf5508d9eede31f65eb39f7f922045728f74da6ae96683a4d62f8be1bd44734
Type fulltextMimetype application/pdf

By organisation
School of Industrial Engineering and Management (ITM)
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 2 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 6 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf